GROUP 6 AUTOMATIC WARMING UP FUNCTION Engine ECM Main pump Pilot pump Max flow CO valve CAN + GND - CAN Warming up lamp signal Drive signal MCU Cluster 51075MS07 1. MCU receives engine coolant temperature from the ECM, and if the coolant temperature is less than 3 0 C , it increases the engine speed from key start rpm to 1000rpm. At this time the mode does not change. 2. In case of the coolant temperature increases up to 3 0 C, the engine speed is decreased to key start speed. And if an operator changes mode set during the warming up function, the MCU cancels the automatic warming up function. 3. LOGIC TABLE 5-9 EPPR valve Description Condition Function Actuated - Coolant temperature :
Less than 30 C (After engine run) - Accel dial position is under 3 - Mode : Default(S mode) - Warming up time : 10 minutes(Max) - Warming up lamp : ON Canceled Warming up la - Coolant temperature : Above 30 C - Warming up time : Above 10 minutes - Changed mode set by operator - Increase engine speed by rotating accel dial clockwise If any of the above conditions is applicable, the automatic warming up function is canceled mp - Coolant temperature : Above 30 C - Default mode - Default mode - Changed mode - Warming up lamp : OFF