hyundai R510LC-7 — 9. SELF-DIAGNOSTIC SYSTEM

5-19 Fault code No. Reason Effect(only when fault code is active) 582 Low voltage detected at the fuel inlet restriction sensor signal pin Fuel inlet restriction monitor deactivated. 583 Restriction has been detected at the fuel pump inlet. Fuel inlet restriction monitor warning is set. 596 High battery voltage detected by the battery voltage monitor feature. Yellow lamp will be lit until high battery voltage condition is corrected. 597 ICONTMhas restarted the engine three times within three hours due to low battery voltage (automotive only) OR low battery voltage detected by the battery voltage monitor feature. Yellow lamp will be lit until low battery voltage condition is corrected.

The ECM may increase idle speed and deactivate idle decrement switch if idle speedup is enabled. The engine will run continuously if ICONTMis active (automotive only). 598 Very low battery voltage detected by the battery voltage monitor feature. Red lamp lit until very low battery voltage condition is corrected. 611 Engine shutdown by operator before proper engine cool down resulting in filtered load factor above maximum shutdown threshold. No action taken by the ECM. 951 A power imbalance between cylinders was detected by the ECM. Engine may have rough idle or misfire.