8. WHEN COOLANT TEMPERATURE GAUGE DOES NOT OPERATE Before disconnecting the connector, always turn the starting switch OFF. Before carrying out below procedure, check all the related connectors are properly inserted. After checking, insert the disconnected connectors again immediately unless otherwise specified. 12th step Check Table 1 st step RESISTOR RESISTOR A A B A A B ECM 3 CN-98 B C B C COOLANT TEMP SENSOR CN-99 CONTROLLER 25 4 46 26 5 37 27 3 36 CN-50 CN-2 51076ES03 6-31 YES Is the CAN YES communication between CPU and ECM? Starting switch : ON YES Does the gauge Check resistance light up and between CN-98 down at lamp NO (A-B) & CN-99 check? (A-B). NO Starting switch : ON Spec :
120 NO Cause Remedy Disconnection in wiring harness or poor contact between ECM-coolant temp sensor Defective controller or ECM Defective wiring harness Defective cluster Repair or replace (After clean) Replace Replace Replace Temperature Item White range (~29 C) Green range (30~105 C) Red range (105 C ~) A B C