GROUP 3 PUMP DEVICE 1. REMOVAL AND INSTALL 1) REMOVAL (1) Lower the work equipment to the ground and stop the engine. (2) Loosen the breather slowly to release the pressure inside the hydraulic tank. Escaping fluid under pressure can penetrate the skin causing serious injury. 13031GE18 (3) Loosen the drain plug under the hydraulic tank and drain the oil from the hydraulic tank. Hydraulic tank quantity : 250 (4) Remove socket bolts(5) and disconnect hose (1,2). 5 1 (5) Disconnect pilot line hoses(4, 5, 6, 7, 8, 9, 10, 11). 2 4 5 3 (6) Remove bolts(4) and disconnect pump suction tube (3). When pump suction tube is disconnected, the oil inside the piping will flow out, so catch it in oil pan.
50078MP01 11 (7) Sling the pump assembly and remove the pump mounting bolts. 7 10 Weight : 180 kg (400 lb ) Pull out the pump assembly from housing. When removing the pump assembly, check that all the hoses have been disconnected. 8 A2 6 9 50078MP02 8-7