(3) Power shift control The set horsepower valve is shifted by varying the command current level of the proportional pressure reducing valve attached to the pump. Only one proportional pressure reducing valve is provided. However, the secondary pressure Pf (power shift pressure) is admitted to the horsepower control section of each pump regulator through the pump's internal path to shift it to the same set horsepower level. This function permits arbitrary setting of the pump output power, thereby providing the optimum power level according to the operating condition. The power shift pressure Pf controls the set horsepower of the pump to a desired level, as shown in the figure.
As the power shift pressure Pf rises, the compensating rod(623) moves to the right via the pin(898) and compensating piston(621). This decreases the pump tilting angle and then the set horsepower in the same way as explained in the overload preventive function of the horsepower control. On the contrary, the set horsepower rises as the power shift pressure Pf falls. 45070RG11 Delivery flow, Q P f =MAX. P f =MIN. Delivery pressure, (P1+P2) 2-19