hyundai R510LC-7 — 1. PUMP DEVICE

(5) Qmax cut control The regulator regulates the maximum delivery flow by inputting the pilot pressure Pm. Since this is a 2-position control method, the maximum delivery flow may be switched in two steps by turning on/off the pilot pressure Pm.(The maximum control flow cannot be controlled in intermediate level.) Functional explanation As shown in the figure, the pilot pressure Pm switches the maximum flow in two steps. When the pilot pressure Pm is given, it is admitted to the lefthand side of the piston QMC(648). The piston QMC moves the stopper(647) and pilot piston(643) to the right, overcoming the force of the pilot spring(646), thereby reducing the delivery flow of the pump.

Since the adjusting screw QMC(642) is provided with a flange, the piston QMC stops upon contact with the flange, and the position of the pilot piston at this time determines the maximum flow of the pump. 647 648 723 642 438 801 801 924 641 730 643 708 644 645 646 728 2-4 Delivery flow, Q Pm Pilot pressure, Pi Adjustment of Qmax cut flow Adjust it by loosening the hexagon nut(801) and by tightening(or loosening) the adjusting screw QMC(642). Tightening the screw decreases the Qmax cut flow as shown in the figure. Delivery flow, Q Pilot pressure, Pi 2-21