BF135A•BF150A 5-16 DTC PGM-FI MIL Detected unit Probable problem part Ref.
page 10-1 MIL comes ON IAT sensor (Voltage too low) • Short circuit in IAT sensor wire • Faulty IAT sensor • Faulty ECM 5-38 10-2 MIL comes ON IAT sensor (Voltage too high) • Open circuit in IAT sensor wire • Faulty IAT sensor • Faulty ECM 5-38 13-1 MIL comes ON BARO sensor (Voltage too low) • Short circuit in BARO sensor wire • Faulty BARO sensor • Faulty ECM 5-39 13-2 MIL comes ON BARO sensor (Voltage too high) • Open circuit in BARO sensor wire • Faulty BARO sensor • Faulty ECM 5-40 14-1 MIL comes ON IAC valve (Abnormal current flow) • Open/short circuit in IAC valve wire • Faulty IAC valve • Faulty ECM 5-41 21-1 MIL comes ON VTEC solenoid valve (Abnormal output)(BF150A only) • Open/short circuit in VTEC solenoid valve • Faulty VTEC solenoid valve • Faulty ECM 5-42 23-1 MIL comes ON Knock sensor (Abnormal detection) • Open/short circuit in knock sensor wire • Faulty knock sensor • Faulty ECM 5-43 41-3 MIL comes ON A/F sensor heater (Abnormal current flow) • Open/short circuit in A/F sensor heater wire • Faulty A/F sensor heater • Faulty ECM 5-44 41-4 MIL comes ON A/F sensor heater (Abnormal current flow) • Open/short circuit in A/F sensor heater wire • Faulty A/F sensor heater • Faulty ECM 5-46 48-5 MIL comes ON A/F sensor heater (Abnormal current flow) • Open circuit in A/F sensor heater wire • Faulty A/F sensor • Faulty ECM 5-49 48-6 MIL comes ON A/F sensor heater (Abnormal current flow) • Short circuit in A/F sensor wire C line • Faulty A/F sensor • Faulty ECM 5-50 48-7 MIL comes ON A/F sensor heater (Abnormal current flow) • Short circuit in A/F sensor wire V line • Faulty A/F sensor • Faulty ECM 5-50