honda — Thermostat/Relief Valve/Flush Valve

1. THERMOSTAT a. DISASSEMBLY 1) Remove the engine cover (P. 4-2). 2) Disconnect the water relief tube A from the thermostat cover. Do not reuse the thermostat cover O-ring. Replace it with a new one on reassembly. 3) Remove the thermostat. 4) Disconnect the 2P connectors from the ECT sensor 2 and 4, and remove the ECT sensor 2 and 4. Do not reuse the 9.5 x 1.9 mm O-rings. Replace them with the new ones on reassembly. 5) Release the breather tube from the 18.5 mm clamp of the harness clip bracket B. 6) Remove the two 6 x 14 mm flange bolts from the harness clip bracket B.

With the harness clip bracket B raised a little, remove the harness band clip and the wire harness clip from the harness clip bracket B. [1] THERMOSTAT COVER 6 x 22 (3) [3] WATER RELIEF TUBE A [2] TUBE CLAMP D25.0 [14] THERMOSTAT COVER O-RING [4] HARNESS CLIP BRACKET B [13] THERMOSTAT (60˚C: For cylinder block) [12] ECT SENSOR 4 6 x 14 (2) [11] 9.5 x 1.9 mm O-RING (2) [10] THERMOSTAT (50˚C: For cylinder head) [9] ECT SENSOR 2 [5] 18.5 mm CLAMP [8] BREATHER TUBE [7] WIRE HARNESS CLIP [6] HARNESS BAND CLIP 8-2