honda — Cylinder Heads/Valves

• CAMSHAFT OIL CLEARANCE 1) Clean the camshaft and check the journals for wear and damage. [1] PLASTIGAUGE 2) Clean the rocker shaft holder bearings and the camshaft holder bearings. Install the rocker shaft holders and the camshaft on the cylinder head assembly. 3) Set a plastigauge on each journal as shown. NOTICE Set a plastigauge in the axial direction on each journal. Do not turn the camshaft during the check. 4) Install the camshaft holder on the rocker shaft holder and tighten the bolts to the specified torque (P. 10-35). TORQUE: Head cover bolt, 8 x 90 mm flange bolt, 8 x 110 mm flange bolt: 22 N . m (2.2 kgf . m, 16 lbf . ft) 6 x 20 mm flange bolt, 6 x 32 mm flange bolt: 12 N .

m (1.2 kgf . m, 9 lbf . ft) 5) Remove the camshaft holder. Measure the width of the pressed part of the plastigauge using a scale printed on the bag of the plastigauge. NOTICE Measure the widest width on the plastigauge. [1] SCALE 6) If the measurement exceeds the service limit, replace the camshaft holder, rocker shaft holder and the cylinder head as a set. Recheck the camshaft oil clearance. If the measurement still exceeds the service limit, replace the camshaft. [2] PLASTIGAUGE 10-14 STANDARD SERVICE LIMIT No.1 0.030 – 0.069 mm (0.0012 – 0.0027 in) 0.15 mm (0.006 in) No.2 – No.5 0.060 – 0.099 mm (0.0024 – 0.0039 in) 0.15 mm (0.006 in)