honda — Cylinder Heads/Valves

• CAMSHAFT AXIAL CLEARANCE 1) Install the rocker shaft holder, camshaft and the camshaft holder, and tighten the bolts to the specified torque (P. 10- 35). 2) Put the camshaft at the top dead center of the compression stroke of the No.1 piston (with the dowel pin at your side). Install the dial indicator. 3) Check the camshaft axial play by pushing and pulling the camshaft of the opposite side from the indicator. 4) If the measurement exceeds the service limit, replace the camshaft holder, rocker shaft holder and the cylinder head as a set, and recheck. If the measurement still exceeds the service limit, replace the camshaft. [1] Dowel pin is at your side.

• CAMSHAFT RUNOUT 1) Place the V blocks or equivalent under the journal at both ends of the camshaft 2) Install the dial indicator and measure the camshaft runout by turning the camshaft. 3) Replace the camshaft if the measurement exceeds the service limit. • ROCKER SHAFT O.D. Measure the rocker shaft O.D. at the sliding part of the rocker arm. NOTICE 10-15 STANDARD SERVICE LIMIT 0.05 – 0.20 mm (0.002 – 0.008 in) 0.4 mm (0.02 in) STANDARD SERVICE LIMIT 0.03 mm (0.001 in) Max. 0.4 mm (0.02 in) STANDARD SERVICE LIMIT IN/EX 16.983 – 16.994 mm (0.6686 – 0.6690 in)