6) Check the pump impeller for cracks, wear or damage from overheating, and replace if necessary. 7) Remove the pump impeller, pump liner and the water pump O-ring from the impeller housing. Replace the O-ring with a new one on assembly. [1] IMPELLER HOUSING [2] PUMP LINER [3] PUMP IMPELLER [4] WATER PUMP O-RING 8) Remove the two 6 x 20 mm flange bolts and remove the water seal housing. [1] WATER SEAL HOUSING 9) Remove the 58.5 x 3.5 mm O-ring from the water seal housing. Replace the O-ring with a new one on assembly. 6 x 20 (2) [2] 58.5 x 3.5 mm O-RING 10) Before removing the 23 x 36 x 6 mm water seal, check the water seal lip for cut. Replace if necessary.
[1] WATER SEAL HOUSING 11) Remove the two 23 x 36 x 6 mm water seals from the water seal housing using a commercially available oil seal remover. Replace the water seals with the new ones on assembly. [2] 23 x 36 x 6 mm WATER SEALS 14-8