7. POWER TILT MOTOR ASSEMBLY [1] CORRUGATED TUBE [2] 4 x 16 mm SCREW (Stainless steel) a. DISASSEMBLY 1) Untape the corrugated tube and pull the tube to the connector side. [5] WIRE HOLDER [3] YOKE ASSEMBLY 2) Remove the 4 x 16 mm screw. Pull out the wire holder and the two grommets from the yoke assembly and move them to the corrugated tube side. Pull out the grommets with care not to damage them. NOTICE 3) Remove the two 4 x 16 mm screws. [4] GROMMETS 4) Wrap the armature shaft with a shop towel or equivalent material to protect, and hold the shaft with pliers. Pushing the two motor wires toward the yoke assembly, remove the armature/front bracket assembly from the yoke assembly.
5) Remove the armature from the front bracket. Do not allow the commutator to become contaminated with oil or grease. [2] ARMATURE [1] SHOP TOWEL 6) Remove the two brush springs (P. 15-54). 7) Disconnect the motor wire (blue wire) terminal from the breaker assembly while holding the breaker assembly with a screwdriver. [3] MOTOR WIRES NOTICE [4] YOKE ASSEMBLY Do not disconnect the blue wire terminal without holding the breaker assembly, or it can cause damage to the brush holder B. Be sure to disconnect the terminal while holding the breaker assembly. [5] PLIERS [1] FRONT BRACKET ASSEMBLY [2] BRUSH ASSEMBLY 8) Remove the 4 x 10 mm screw from the brush holder A and remove the brush assembly.
Take care not to touch the bimetal part of the breaker assembly during removal. [3] BRUSH HOLDER A 9) Remove the oil seal from the front bracket assembly (P. 15- 54). [7] BLUE WIRE [4] 4 x 10 mm SCREW Check the metal part of the front bracket assembly for damage and wear. Replace the front bracket assembly if necessary. [6] TERMINAL [5] GREEN WIRE 15-53