3. SEAL HOLDER 6 x 20 (2) a. REMOVAL [1] SEAL HOLDER Remove the following pars. – Engine cover (P. 4-2) – Front separate cover (P. 4-7) – R. engine under cover (P. 4-9) – Remote control cable/bracket (P. 17-2) – Shift link bracket/neutral switch (P. 17-11) 1) Remove the 6 x 14 mm flange bolt from the cable bracket A, and remove the cable bracket A. Remove the starter cable and the alternator fuse cable from the cable bracket A. 2) Remove the two 6 x 20 mm flange bolts from the seal holder, and remove the seal holder. NOTICE [4] CABLE BRACKET A Remove the seal holder with care not to raise the shift shaft B.
[2] STARTER CABLE 6 x 14 Correct the shift shaft B if it is raised or if it is disengaged from the shift shaft A in the mounting case (P. 17-21). [3] ALTERNATOR FUSE CABLE Note that assembly with the shift shaft A and B out of alignment will prevent proper shifting. b. DISASSEMBLY 1) Before removing the 12 x 26 x 7 mm oil seal, check the oil seal lip for cut or other damage. Replace if necessary. [1] 12 x 26 x 7 mm OIL SEAL 2) Remove the 12 x 26 x 7 mm oil seal from the seal holder using a commercially available oil seal remover. Replace the oil seal with a new one on assembly. [2] SEAL HOLDER 3) Remove the 25 x 2.4 mm O-ring from the seal holder.
Replace the O-ring with a new one on assembly. [3] 25 x 2.4 mm O-RING 17-20