honda — Electrical Equipment

d. INSPECTION Use a known-good battery. Do not connect the battery for more than 30 seconds. Wait for one minute or more before connecting the battery again. NOTICE • PGM-FI MAIN RELAY 1) Connect the battery positive (+) terminal to the Black/Yellow terminal of the PGM-FI main relay 6P connector and the battery negative (–) terminal to the Black terminal. There must be the continuity between the following terminals of the 4P connector.

Between White/Yellow and White/Green terminals Between White/Yellow and White/Red terminals Between White/Yellow and White/Black terminals [1] CONNECTORS VIEWED FROM THE FRONT SIDE W/G W/R W/Bl Bu/R 2) Connect the battery positive (+) terminal to the PGM-FI main relay terminal and the battery negative (–) terminal to the Light green/Red terminal. There must be the continuity between the White/Black and the Blue/Red terminals of the 2P connector. W/Y W/Bl 3) Connect the battery positive (+) terminal to the Black/White terminal of the PGM-FI main relay 6P connector and the battery negative (–) terminal to the Black/Blue terminal.

There must be continuity between the terminal and the White/Yellow terminal of the 4P connector. Bl/Y Lg/R Bl Bl/W Bl/Bu 4) Connect the battery positive (+) terminal to the White/ Green terminal of the PGM-FI main relay 4P connector and the battery negative (–) terminal to the 6P connector Light green/Red terminal. There must be continuity between the White/Black and the Blue/Red terminals of the 2P connector. [1] 4P CONNECTOR [2] PGM-FI MAIN RELAY W/G 5) If there is no continuity, replace the PGM-FI main relay. W/Bl W/R W/Y [3] 2P CONNECTOR W/Bl Bu/R [4] 6P CONNECTOR Bl/Bu Bl/W Lg/R Bl/Y Bl [5] TERMINAL 18-24