Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

102 7 SPN 6~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 636 3 S L Camshaft position sensor, short circuit to +24V ECM 636 4 S E Camshaft position sensor, short circuit to ground ECM 636 4 S L Camshaft position sensor, short circuit to ground ECM 636 5 S E Camshaft position sensor, open circuit ECM 636 5 S L Camshaft position sensor, open circuit ECM 636 1 S E Camshaft position sensor, faulty ECM 636 1 S F Camshaft position sensor, faulty ECM 636 1 S L Camshaft position sensor, faulty ECM 636 2 S E Camshaft position sensor, inter- mittent fault ECM 636 2 S F Camshaft position sensor, inter- mittent fault ECM 636 2 S L Camshaft position sensor, inter- mittent fault ECM 636 3 S F Camshaft position sensor, short circuit to +24V ECM 636 4 S F Camshaft position sensor, short circuit to ground ECM 636 5 S F Camshaft position sensor, open circuit ECM 636 7 S E Engine speed detected by fly- wheel sensor, but no signal from camshaft sensor ECM 636 7 S F Engine speed detected by fly- wheel sensor, but no signal from camshaft sensor ECM 636 7 S L Engine speed detected by fly- wheel sensor, but no signal from camshaft sensor ECM 636 8 S E Camshaft Pulse Pattern, Gap or Sync Error or other fault ECM 636 8 S F Camshaft Pulse Pattern, Gap or Sync Error or other fault ECM 636 8 S L Camshaft Pulse Pattern, Gap or Sync Error or other fault ECM 637 11 P E Engine Timing Sensor:

Other Failure Mode ECM 637 11 P L Engine Timing Sensor: Other Failure Mode ECM 638 6 C F Rack Actuator Position #1 Cir- cuit - grounded circuit ECM 638 7 C F Rack Actuator - mechanically stuck open ECM 6385 3 C E Engine Starter Motor Relay Control Circuit - Voltage Above Normal or Shorted to High Source ECM 6385 3 C L Engine Starter Motor Relay Control Circuit - Voltage Above Normal or Shorted to High Source ECM 6385 4 C E Engine Starter Motor Relay Control Circuit - Voltage Below Normal or Shorted to Low Source ECM 6385 4 C L Engine Starter Motor Relay Control Circuit - Voltage Below Normal or Shorted to Low Source ECM 639 14 P E J1939 Network #1 :

Special In- struction ECM 639 14 P L J1939 Network #1 : Special In- struction ECM 639 13 C E SAE J1939 Multiplexing Config- uration Error - Out of Calibration continued.......... ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 639 13 C L SAE J1939 Multiplexing Config- uration Error - Out of Calibration ECM 639 2 C E J1939 Network #1 - Data erratic, intermittent or incorrect ECM 639 2 C F Engine Control Module Network Communication Error ECM 639 2 C L J1939 Network #1 - Data erratic, intermittent or incorrect ECM 639 13 C F SAE J1939 Datalink :

SAE J1939 Multiplexing Configura- tion Error - Out of Calibration ECM 639 9 C E SAE J1939 Datalink - Abnormal update rate ECM 639 9 C F J1939 Datalink - Abnormal Up- date Rate. Communication be- tween the electronic control module (ECM) and another de- vice on the SAE J1939 data link has been lost. ECM 639 9 C L SAE J1939 Datalink - Abnormal update rate ECM 639 9 P E J1939 Network #1 : Abnormal Update Rate ECM 639 9 P L J1939 Network #1 :

Abnormal Update Rate TCU 64 * * L STARTING GEAR SIGNAL TCU 64 * * F STARTING GEAR SIGNAL ECM 640 14 C F OEM Commanded Dual Output Shutdown ECM 640 14 C E Auxiliary Commanded Dual Out- put Shutdown - Special Instruc- tions ECM 640 14 C L Auxiliary Commanded Dual Out- put Shutdown - Special Instruc- tions ECM 641 10 S E VGT motion error, span too large ECM 641 10 S L VGT motion error, span too large ECM 641 11 S E VGT actuator faulty ECM 641 11 S L VGT actuator faulty ECM 641 12 S E VGT internal fault ECM 641 12 S L VGT internal fault ECM 641 11 C E VGT Actuator Driver Circuit - Root Cause Not Known ECM 641 11 C L VGT Actuator Driver Circuit - Root Cause Not Known ECM 641 31 C F VGT Actuator Driver Circuit - Condition Exists ECM 641 9 C F VGT Actuator Driver Circuit - Abnormal update rate ECM 641 31 C E VGT Actuator Driver Circuit - Condition Exists ECM 641 31 C L VGT Actuator Driver Circuit - Condition Exists ECM 641 11 C F VGT Actuator Driver Circuit - Root Cause Not Known ECM 641 12 C F VGT Actuator Controller - Bad intelligent device or component ECM 641 13 C F VGT Actuator Controller - Out of Calibration ECM 641 15 C F Variable geometry turbocharger actuator over temperature (cal- culated) - data above normal range - least severe level.

ECM 641 12 C E VGT Actuator Controller - Bad intelligent device or component continued..........