Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

103 7 SPN 6~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 641 12 C L VGT Actuator Controller - Bad intelligent device or component ECM 641 3 C F VGT actuator driver circuit - volt- age above normal or shorted to high source. ECM 641 4 C F VGT actuator driver circuit - volt- age below normal, or shorted to low source. ECM 641 13 C E VGT Actuator Controller - Out of Calibration ECM 641 13 C L VGT Actuator Controller - Out of Calibration ECM 641 5 C F Variable Geometry Turbocharg- er actuator circuit - current be- low normal, or open circuit.

ECM 641 13 S E VGT actuator installation proce- dure was not completed ECM 641 13 S L VGT actuator installation proce- dure was not completed ECM 641 15 C E VGT Actuator Driver Over Tem- perature (Calculated) - Data Valid But Above Normal Operat- ing Range - Least Severe Level ECM 641 7 C F VGT Actuator Driver Circuit (Motor) - Mechanical system not responding or out of adjustment ECM 641 15 C L VGT Actuator Driver Over Tem- perature (Calculated) - Data Valid But Above Normal Operat- ing Range - Least Severe Level ECM 641 15 S E VGT error ECM 641 15 S L VGT error ECM 641 16 S E VGT temperature too high ECM 641 16 S L VGT temperature too high ECM 641 19 S E VGT timeout on CAN ECM 641 19 S L VGT timeout on CAN ECM 641 2 S E VGT internal temperature sen- sor stuck ECM 641 2 S L VGT internal temperature sen- sor stuck ECM 641 20 S E Variable geometry turbocharger control fault ECM 641 20 S L Variable geometry turbocharger control fault ECM 641 4 S E VGT voltage supply open load ECM 641 4 S L VGT voltage supply open load ECM 641 5 S E VGT internal temperature sen- sor open circuit ECM 641 5 S L VGT internal temperature sen- sor open circuit ECM 641 7 C E VGT Actuator Driver Circuit (Motor) - Mechanical system not responding or out of adjustment ECM 641 7 C L VGT Actuator Driver Circuit (Motor) - Mechanical system not responding or out of adjustment ECM 641 7 S E VGT motion limited or restricted ECM 641 7 S L VGT motion limited or restricted ECM 641 8 S E VGT reference or position not found ECM 641 8 S L VGT reference or position not found ECM 641 9 C E VGT Actuator Driver Circuit - Abnormal update rate ECM 641 9 C L VGT Actuator Driver Circuit - Abnormal update rate continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 641 9 S E VGT temperature sensor value not plausible ECM 641 9 S L VGT temperature sensor value not plausible ECM 641 10 S F VGT motion error, span too large ECM 641 11 S F VGT actuator faulty ECM 641 12 S F VGT internal fault ECM 641 13 S F VGT actuator installation proce- dure was not completed ECM 641 15 S F VGT error ECM 641 16 S F VGT temperature too high ECM 641 19 S F VGT timeout on CAN ECM 641 2 S F VGT internal temperature sen- sor stuck ECM 641 4 S F VGT voltage supply open load ECM 641 5 S F VGT internal temperature sen- sor open circuit ECM 641 6 C E VGT Actuator Driver Circuit - Current Above Normal or Grounded Circuit ECM 641 6 C L VGT Actuator Driver Circuit - Current Above Normal or Grounded Circuit ECM 641 6 S E Variable geometry turbocharger control fault ECM 641 6 S L Variable geometry turbocharger control fault ECM 641 7 S F VGT motion limited or restricted ECM 641 8 S F VGT reference or position not found ECM 641 9 S F VGT temperature sensor value not plausible ECM 644 2 C E External Speed Command Input (Multiple Unit Synchronization) - Data erratic, intermittent or in- correct ECM 644 2 C F External Speed Input (Multiple Unit Sychronization) - data in- correct ECM 644 2 C L External Speed Command Input (Multiple Unit Synchronization) - Data erratic, intermittent or in- correct ECM 645 19 S E CAN message TCO1 from ta- chograph timeout ECM 645 19 S F CAN message TCO1 from ta- chograph timeout ECM 645 19 S L CAN message TCO1 from ta- chograph timeout ECM 647 3 C F Fan Control Circuit - Voltage Above Normal or Shorted to High Source.

Open circuit or high voltage detected at the fan control circuit. ECM 647 11 C F Fan Clutch Circuit Error ECM 647 3 C E Fan Control Circuit - Voltage above normal, or shorted to high source ECM 647 3 C L Fan Control Circuit - Voltage above normal, or shorted to high source ECM 647 4 C E Fan Control Circuit - Voltage be- low normal, or shorted to low source ECM 647 4 C L Fan Control Circuit - Voltage be- low normal, or shorted to low source continued..........