Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

41 3 SPN 2~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 2791 2 S F EGR actuator, control error ECM 2791 20 S F EGR higher than desired ECM 2791 21 S F EGR lower than desired ECM 2791 3 S F EGR actuator, short circuit to +24V ECM 2791 4 S F EGR actuator, short circuit to ground ECM 2791 5 S F EGR actuator, stuck open ECM 2791 7 S F EGR actuator, stuck close ECM 2791 13 C E EGR Valve Controller - Out of Calibra- tion ECM 2791 8 S F The EGR valve is responding too slow ECM 2791 13 C L EGR Valve Controller - Out of Calibra- tion ECM 2791 8 S E The EGR valve is responding too slow ECM 2791 8 S L The EGR valve is responding too slow ECM 2795 13 C F Variable Geometry Turbocharger ac- tuator position failed automatic calibra- tion procedure - out of calibration.

ECM 2795 2 C F VGT Position Sensor - Data erratic, in- termittent, or incorrect. Intermittent variable geometry turbocharger (VGT) position information is being received by the electronic control module (ECM). ECM 2795 4 C F Turbocharger position sensor circuit - shorted high. High signal voltage de- tected at the turbocharger position sensor circuit.

ECM 2797 13 C F Engine Injector Bank 1 Barcodes - Out of Calibration ECM 2797 3 S E Injector group A, short circuit to +24V ECM 2797 3 S L Injector group A, short circuit to +24V ECM 2797 4 S E Injector group A, short circuit to ground ECM 2797 4 S L Injector group A, short circuit to ground ECM 2797 5 S E Injector drive voltage, faulty ECM 2797 5 S L Injector drive voltage, faulty ECM 2797 6 P E Engine Injector Group 1 : Current Above Normal ECM 2797 6 P L Engine Injector Group 1 : Current Above Normal ECM 2797 6 Y E Injector drive circuit (Bank 1) short cir- cuit (4TN : Common circuit for No. 1, No.

4 and all 3TN cylinders) ECM 2797 6 Y L Injector drive circuit (Bank 1) short cir- cuit (4TN : Common circuit for No. 1, No. 4 and all 3TN cylinders) ECM 2797 7 P E Engine Injector Group 1 : Not Re- sponding Properly ECM 2797 7 P L Engine Injector Group 1 :

Not Re- sponding Properly ECM 2797 13 C E Engine Injector Bank 1 Barcodes - Out of Calibration ECM 2797 2 S F Injector group A, short circuit to other bank ECM 2797 13 C L Engine Injector Bank 1 Barcodes - Out of Calibration ECM 2797 3 S F Injector group A, short circuit to +24V ECM 2797 4 S F Injector group A, short circuit to ground ECM 2797 5 S F Injector drive voltage, faulty ECM 2797 2 S E Injector group A, short circuit to other bank ECM 2797 8 S F Injector group A, injection error continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 2797 2 S L Injector group A, short circuit to other bank ECM 2797 8 S E Injector group A, injection error ECM 2797 8 S L Injector group A, injection error ECM 2798 2 S E Injector group B, short circuit to other bank ECM 2798 2 S L Injector group B, short circuit to other bank ECM 2798 3 S E Injector group B, short circuit +24V ECM 2798 3 S L Injector group B, short circuit +24V ECM 2798 4 S E Injector group B, short circuit ground ECM 2798 4 S L Injector group B, short circuit ground ECM 2798 6 P E Engine Injector Group 2 : Current Above Normal ECM 2798 6 P L Engine Injector Group 2 :

Current Above Normal ECM 2798 6 Y E Injector drive circuit (Bank 2) short cir- cuit (4TN : Circuit for No. 2 and 3 cyl- inders) ECM 2798 6 Y L Injector drive circuit (Bank 2) short cir- cuit (4TN : Circuit for No. 2 and 3 cyl- inders) ECM 2798 2 S F Injector group B, short circuit to other bank ECM 2798 3 S F Injector group B, short circuit +24V ECM 2798 4 S F Injector group B, short circuit ground ECM 2798 8 S F Injection error, group B ECM 2798 8 S E Injection error, group B ECM 2798 8 S L Injection error, group B TCU 28 * * E P2 pressure sensor circuit is open or shorted to ground TCU 28 * * L S.C.

TO GROUND AT RETARDER / TORQUECONVERTER TEMPERA- TURE SENSOR INPUT ECM 28 0 Y E Accelerator sensor 3 error (foot pedal in open position) ECM 28 0 Y L Accelerator sensor 3 error (foot pedal in open position) ECM 28 1 Y E Accelerator sensor 3 error (foot pedal in closed position) ECM 28 1 Y L Accelerator sensor 3 error (foot pedal in closed position) ECM 28 3 Y E Accelerator sensor 2 error (Voltage high) ECM 28 3 Y L Accelerator sensor 2 error (Voltage high) ECM 28 4 Y E Accelerator sensor 2 error (Voltage low) ECM 28 4 Y L Accelerator sensor 2 error (Voltage low) TCU 28 * * F S.C.

TO GROUND AT RETARDER / TORQUECONVERTER TEMPERA- TURE SENSOR INPUT ECM 2802 31 C E Electronic Control Module data lost - Condition Exists ECM 2802 31 C L Electronic Control Module data lost - Condition Exists ECM 2802 31 C F Electronic Control Module : Electronic Control Module data lost - Condition Exists ECM 2840 12 P E ECU Instance: Failure ECM 2840 12 P L ECU Instance: Failure ECM 2840 14 P E ECU Instance: Special Instruction ECM 2840 14 P L ECU Instance: Special Instruction ECM 2858 13 S E EMS, Default EOL Data in E2 continued..........