Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

42 3 SPN 2~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 2858 13 S L EMS, Default EOL Data in E2 ECM 2858 13 S F Machine Data Configuration ECM 2859 13 S E EMS, Default Barcoding Data in E2 ECM 2859 13 S L EMS, Default Barcoding Data in E2 ECM 2860 13 S E EMS internal software error ECM 2860 13 S L EMS internal software error ECM 2861 13 S E EMS Configuration for Automatic Clutch Faulty ECM 2861 13 S L EMS Configuration for Automatic Clutch Faulty ECM 2862 13 S E Internal software error ECM 2862 13 S L Internal software error ECM 2880 3 P E Engine Operator Primary Intermediate Speed Select:

Voltage Above Normal ECM 2880 3 P L Engine Operator Primary Intermediate Speed Select: Voltage Above Normal ECM 2880 4 P E Engine Operator Primary Intermediate Speed Select: Voltage Below Normal ECM 2880 4 P L Engine Operator Primary Intermediate Speed Select: Voltage Below Normal ECM 2880 2 P E Engine Operator Primary Intermediate Speed Select: Erratic, Intermittent, or Incorrect ECM 2880 2 P L Engine Operator Primary Intermediate Speed Select: Erratic, Intermittent, or Incorrect ECM 2882 2 P E Engine Alternate Rating Select : Errat- ic, Intermittent, or Incorrect ECM 2882 2 P L Engine Alternate Rating Select :

Errat- ic, Intermittent, or Incorrect ECM 2884 9 C F Engine Auxiliary Governor Switch - Abnormal update rate ECM 2884 9 C E Engine Auxiliary Governor Switch - Abnormal update rate ECM 2884 9 C L Engine Auxiliary Governor Switch - Abnormal update rate ECM 29 3 C F High voltage detected at the remote throttle position signal circuit. ECM 29 4 C F Low voltage detected at the remote throttle position signal circuit. ECM 29 2 P E Accelerator Pedal Position 2 : Erratic, Intermittent or Incorrect ECM 29 2 P L Accelerator Pedal Position 2 : Erratic, Intermittent or Incorrect ECM 29 3 P E Accelerator Pedal Position 2 : Voltage Above Normal ECM 29 3 P L Accelerator Pedal Position 2 :

Voltage Above Normal ECM 29 3 Y E Accelerator sensor 3 error (Voltage high) ECM 29 3 Y L Accelerator sensor 3 error (Voltage high) ECM 29 4 P E Accelerator Pedal Position 2 : Voltage Below Normal ECM 29 4 P L Accelerator Pedal Position 2 : Voltage Below Normal ECM 29 4 Y E Accelerator sensor 3 error (Voltage low) ECM 29 4 Y L Accelerator sensor 3 error (Voltage low) TCU 29 * * E P3 pressure sensor circuit is open or shorted to ground TCU 29 * * L S.C. TO BATTERY VOLTAGE OR O.C. AT PARKING BRAKE SENSOR INPUT continued.......... ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 29 8 P E Accelerator Pedal Position 2 :

Abnor- mal Frequency, Pulse width or Period ECM 29 8 P L Accelerator Pedal Position 2 : Abnor- mal Frequency, Pulse width or Period ECM 29 8 Y E Pulse accelerator sensor error (pulse communication) ECM 29 8 Y L Pulse accelerator sensor error (pulse communication) TCU 29 * * F S.C. TO BATTERY VOLTAGE OR O.C.

AT PARKING BRAKE SENSOR INPUT ECM 2900 19 C E Transmission Engine Crank Enable - Received Network Data in Error ECM 2900 19 C L Transmission Engine Crank Enable - Received Network Data in Error ECM 2900 9 C E Transmission Engine Crank Enable - Abnormal Update Rate ECM 2900 9 C L Transmission Engine Crank Enable - Abnormal Update Rate ECM 2950 3 Y E Power short circuit of throttle valve drive H bridge output 1 ECM 2950 3 Y L Power short circuit of throttle valve drive H bridge output 1 ECM 2950 4 Y E GND short circuit of throttle valve drive H bridge output 1 ECM 2950 4 Y L GND short circuit of throttle valve drive H bridge output 1 ECM 2950 5 Y E No-load of throttle valve drive H bridge circuit ECM 2950 5 Y L No-load of throttle valve drive H bridge circuit ECM 2950 6 Y E Overload on the drive H bridge circuit of throttle valve ECM 2950 6 Y L Overload on the drive H bridge circuit of throttle valve ECM 2951 3 Y E VB Power short circuit of throttle valve drive H bridge output 2 ECM 2951 3 Y L VB Power short circuit of throttle valve drive H bridge output 2 ECM 2951 4 Y E GND short circuit of throttle valve drive H bridge output 2 ECM 2951 4 Y L GND short circuit of throttle valve drive H bridge output 2 ECM 2970 2 P E Accelerator Pedal 2 Low Idle Switch :

Erratic, Intermittent, or Incorrect ECM 2970 2 P L Accelerator Pedal 2 Low Idle Switch : Erratic, Intermittent, or Incorrect ECM 2971 6 C F Exhaust Gas Recirculation (EGR) valve control circuit - current above normal or grounded circuit. Excess current detected at the EGR valve mo- tor output circuit. ECM 2975 6 C F Turbocharger actuator motor circuit - current is above normal. Excessive current detected at the turbocharger actuator motor circuit. ECM 2975 7 C F Turbocharger actuator motor - the me- chanical system is not responding properly or is out of adjustment. Tur- bocharger actuator is not responding or is slow to respond.

ECM 2978 9 C F Estimated Engine Parasitic Losses - Percent Torque - Abnormal update rate ECM 2978 9 C E Estimated Engine Parasitic Losses - Percent Torque - Abnormal update rate ECM 2978 9 C L Estimated Engine Parasitic Losses - Percent Torque - Abnormal update rate continued..........