46 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3216 2 S L NOx sensor T131 upstream of the SCR catalytic converter indicates in- correct values.
ECM 3216 20 C E Aftertreatment 1 Intake NOx Sensor - Data not Rational - Drifted High ECM 3216 20 C L Aftertreatment 1 Intake NOx Sensor - Data not Rational - Drifted High ECM 3216 20 S E NOx sensor upstream, not plausible ECM 3216 20 S L NOx sensor upstream, not plausible ECM 3216 4 C E Aftertreatment 1 Intake NOx Sensor Circuit - Voltage below normal, or shorted to low source ECM 3216 4 C L Aftertreatment 1 Intake NOx Sensor Circuit - Voltage below normal, or shorted to low source ECM 3216 4 S E NOx sensor upstream, internal fault or open circuit ECM 3216 4 S L NOx sensor upstream, internal fault or open circuit ECM 3216 5 P E Aftertreatment #1 Intake NOx - Cur- rent Below Normal ECM 3216 5 P L Aftertreatment #1 Intake NOx - Cur- rent Below Normal ECM 3216 5 S E NOx sensor upstream, open circuit ECM 3216 5 S L NOx sensor upstream, open circuit ECM 3216 6 P E Aftertreatment #1 Intake NOx - Cur- rent Above Normal ECM 3216 6 P L Aftertreatment #1 Intake NOx - Cur- rent Above Normal ECM 3216 6 S E Fault in the voltage supply to NOx sensor T131 upstream of the SCR catalytic converter.
ECM 3216 6 S L Fault in the voltage supply to NOx sensor T131 upstream of the SCR catalytic converter.
ECM 3216 7 P E Aftertreatment #1 Intake NOx - Not Responding Properly ECM 3216 7 P L Aftertreatment #1 Intake NOx - Not Responding Properly ECM 3216 7 S E NOx sensor upstream, internal fault ECM 3216 7 S L NOx sensor upstream, internal fault ECM 3216 8 S E NOx sensor upstream of catalytic converter ECM 3216 8 S L NOx sensor upstream of catalytic converter ECM 3216 9 C E Aftertreatment 1 Intake NOx Sensor - Abnormal update rate ECM 3216 9 C L Aftertreatment 1 Intake NOx Sensor - Abnormal update rate ECM 3216 9 S E NOx sensor upstream of catalytic converter ECM 3216 9 S L NOx sensor upstream of catalytic converter ECM 3216 10 S F NOx sensor upstream, stuck ECM 3216 17 S F NOx sensor upstream, low signal ECM 3216 18 S F NOx sensor upstream, too low value ECM 3216 13 C E Aftertreatment 1 Intake NOx - Out of Calibration ECM 3216 19 S F NOx sensor upstream error via CAN ECM 3216 13 C L Aftertreatment 1 Intake NOx - Out of Calibration ECM 3216 19 S E NOx sensor upstream error via CAN ECM 3216 19 S L NOx sensor upstream error via CAN ECM 3216 2 S F Aftertreatment Intake NOx ECM 3216 20 S F NOx sensor upstream, not plausible continued..........
...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3216 2 C E Aftertreatment 1 Intake NOx Sensor - Data erratic, intermittent or incor- rect ECM 3216 2 C L Aftertreatment 1 Intake NOx Sensor - Data erratic, intermittent or incor- rect ECM 3216 4 S F NOx sensor upstream, internal fault or open circuit ECM 3216 5 S F NOx sensor upstream, open circuit ECM 3216 6 S F Aftertreatment Intake NOx ECM 3216 7 S F NOx sensor upstream, internal fault ECM 3216 8 S F NOx sensor upstream of catalytic converter ECM 3216 9 S F NOx sensor upstream of catalytic converter ECM 3216 21 C E Aftertreatment 1 Intake NOx Sensor - Data not Rational - Drifted High ECM 3216 21 C L Aftertreatment 1 Intake NOx Sensor - Data not Rational - Drifted High ECM 3217 2 C F Aftertreatment Intake Oxygen Sen- sor - Data erratic, intermittent or in- correct ECM 3217 12 P E Aftertreatment #1 Intake 02 :
Failure ECM 3217 12 P L Aftertreatment #1 Intake 02 : Failure ECM 3217 13 P E Aftertreatment #1 Intake 02 : Out of Calibration ECM 3217 13 P L Aftertreatment #1 Intake 02 : Out of Calibration ECM 3217 16 P E Aftertreatment #1 Intake O2 : High - moderate severity (2) ECM 3217 16 P L Aftertreatment #1 Intake O2 :
High - moderate severity (2) ECM 3217 20 C E Aftertreatment Intake Oxygen Sen- sor - Data Not Rational - Drifted High ECM 3217 20 C L Aftertreatment Intake Oxygen Sen- sor - Data Not Rational - Drifted High ECM 3217 21 C E Aftertreatment Intake Oxygen Sen- sor - Data Not Rational - Drifted Low ECM 3217 21 C L Aftertreatment Intake Oxygen Sen- sor - Data Not Rational - Drifted Low ECM 3217 3 P E Aftertreatment #1 Intake 02 : Volt- age Above Normal ECM 3217 3 P L Aftertreatment #1 Intake 02 : Volt- age Above Normal ECM 3217 4 P E Aftertreatment #1 Intake 02 : Volt- age Below Normal ECM 3217 4 P L Aftertreatment #1 Intake 02 : Volt- age Below Normal ECM 3217 5 P E Aftertreatment #1 Intake 02 :
Cur- rent Below Normal ECM 3217 5 P L Aftertreatment #1 Intake 02 : Cur- rent Below Normal ECM 3217 6 P E Aftertreatment #1 Intake 02 : Cur- rent Above Normal ECM 3217 6 P L Aftertreatment #1 Intake 02 : Cur- rent Above Normal ECM 3217 15 P E Aftertreatment #1 Intake 02 : High - least severe (1) ECM 3217 15 P L Aftertreatment #1 Intake 02 : High - least severe (1) ECM 3217 2 C E Aftertreatment Intake Oxygen Sen- sor - Data erratic, intermittent or in- correct ECM 3217 2 C L Aftertreatment Intake Oxygen Sen- sor - Data erratic, intermittent or in- correct continued..........