Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

47 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3218 2 C F Aftertreatment 1 Intake NOx Sensor Power Supply - Data erratic, inter- mittent or incorrect ECM 3218 12 P E Aftertreatment #1 Intake NOx : fail- ure ECM 3218 12 P L Aftertreatment #1 Intake NOx : fail- ure ECM 3218 2 C E Aftertreatment 1 Intake NOx Sensor Power Supply - Data erratic, inter- mittent or incorrect ECM 3218 2 C L Aftertreatment 1 Intake NOx Sensor Power Supply - Data erratic, inter- mittent or incorrect ECM 3219 15 P E Aftertreatment #1 Intake Gas Sen- sor at Temperature: High -least se- vere (1) ECM 3219 15 P L Aftertreatment #1 Intake Gas Sen- sor at Temperature:

High -least se- vere (1) ECM 3219 17 P E Aftertreatment #1 Intake Gas Sen- sor at Temperature: Low -least se- vere (1) ECM 3219 17 P L Aftertreatment #1 Intake Gas Sen- sor at Temperature:

Low -least se- vere (1) MCU 322 3 * E Engine Preheat Relay-Voltage Above Normal, Or Shorted To High Source MCU 322 3 * L Engine Preheat Relay-Voltage Above Normal, Or Shorted To High Source MCU 322 4 * E Engine Preheat Relay-Voltage Be- low Normal, Or Shorted To Low Source MCU 322 4 * L Engine Preheat Relay-Voltage Be- low Normal, Or Shorted To Low Source MCU 322 6 * E Engine Preheat Relay-Current Above Normal Or Grounded Circuit MCU 322 6 * L Engine Preheat Relay-Current Above Normal Or Grounded Circuit MCU 322 4 * F Engine Preheat Relay Circuit .

Volt- age Below Normal, or Shorted to Low Source (or Open Circuit) MCU 322 6 * F Engine Preheat Relay Circuit - Cur- rent Above Normal ECM 3222 3 P E Aftertreatment #1 Intake Gas Sen- sor Heater: Voltage Above Normal ECM 3222 3 P L Aftertreatment #1 Intake Gas Sen- sor Heater: Voltage Above Normal ECM 3222 4 P E Aftertreatment #1 Intake Gas Sen- sor Heater: Voltage Below Normal ECM 3222 4 P L Aftertreatment #1 Intake Gas Sen- sor Heater: Voltage Below Normal ECM 3222 5 P E Aftertreatment #1 Intake Gas Sen- sor Heater: Current Below Normal ECM 3222 5 P L Aftertreatment #1 Intake Gas Sen- sor Heater:

Current Below Normal ECM 3226 11 C E Aftertreatment 1 Outlet NOx Sensor - Root Cause Not Known ECM 3226 11 C L Aftertreatment 1 Outlet NOx Sensor - Root Cause Not Known ECM 3226 0 C F Aftertreatment Outlet NOx - Data Valid but Above Normal Operational Range - Most Severe Level. The en- gine NOx output is higher than rec- ommended levels. ECM 3226 10 C F Aftertreatment 1 Outlet NOx Sensor - Abnormal rate of change ECM 3226 13 C F Aftertreatment 1 Outlet NOx Sensor - Out of Calibration continued.......... ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3226 15 C F Aftertreatment Outlet NOx - Data Valid but Above Normal Operational Range - Least Severe Level.

The engine NOx output is higher than recommended levels.

ECM 3226 2 C F Aftertreatment 1 Outlet NOx Sensor - Data erratic, intermittent or incor- rect ECM 3226 20 C F Aftertreatment 1 Outlet NOx Sensor - Data not Rational - Drifted High ECM 3226 4 C F Aftertreatment 1 Outlet NOx Sensor Circuit - Voltage below normal, or shorted to low source ECM 3226 9 C F Aftertreatment 1 Outlet NOx Sensor - Abnormal update rate ECM 3226 10 C E Aftertreatment 1 Outlet NOx Sensor - Abnormal rate of change ECM 3226 10 C L Aftertreatment 1 Outlet NOx Sensor - Abnormal rate of change ECM 3226 10 S E NOx sensor downstream, stuck ECM 3226 10 S L NOx sensor downstream, stuck ECM 3226 11 P E ECM 3226 11 P L ECM 3226 12 P E ECM 3226 12 P L ECM 3226 17 S E NOx sensor downstream, low signal ECM 3226 17 S L NOx sensor downstream, low signal ECM 3226 18 S E NOx sensor downstream, too low value ECM 3226 18 S L NOx sensor downstream, too low value ECM 3226 19 S E NOx sensor downstream of the cat- alytic converter ECM 3226 19 S L NOx sensor downstream of the cat- alytic converter ECM 3226 2 C E Aftertreatment 1 Outlet NOx Sensor - Data Erratic, Intermittant, or Incor- rect.

ECM 3226 2 C L Aftertreatment 1 Outlet NOx Sensor - Data Erratic, Intermittant, or Incor- rect.

ECM 3226 2 S E Nox sensor downstream, Implausi- ble signal ECM 3226 2 S L Nox sensor downstream, Implausi- ble signal ECM 3226 20 C E Aftertreatment 1 Outlet NOx Sensor - Data not Rational - Drifted High ECM 3226 20 C L Aftertreatment 1 Outlet NOx Sensor - Data not Rational - Drifted High ECM 3226 20 S E NOx sensor downstream, not plausi- ble ECM 3226 20 S L NOx sensor downstream, not plausi- ble ECM 3226 4 C E Aftertreatment Outlet NOx Sensor Circuit- Voltage below normal or shorted to low source ECM 3226 4 C L Aftertreatment Outlet NOx Sensor Circuit- Voltage below normal or shorted to low source ECM 3226 4 S E NOx sensor downstream, internal fault or open circuit ECM 3226 4 S L NOx sensor downstream, internal fault or open circuit ECM 3226 5 P E Aftertreatment #1 Outlet NOx :

Cur- rent Below Normal ECM 3226 5 P L Aftertreatment #1 Outlet NOx : Cur- rent Below Normal continued..........