Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

48 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3226 5 S E NOx sensor downstream, open cir- cuit ECM 3226 5 S L NOx sensor downstream, open cir- cuit ECM 3226 6 P E Aftertreatment #1 Outlet NOx : Cur- rent Above Normal ECM 3226 6 P L Aftertreatment #1 Outlet NOx : Cur- rent Above Normal ECM 3226 6 S E Fault in the voltage supply to NOx sensor T115 downstream of the SCR catalytic converter. ECM 3226 6 S L Fault in the voltage supply to NOx sensor T115 downstream of the SCR catalytic converter.

ECM 3226 7 C E Aftertreatment 1 Outlet NOx Sensor Closed Loop Operation - Condition Exists ECM 3226 7 C L Aftertreatment 1 Outlet NOx Sensor Closed Loop Operation - Condition Exists ECM 3226 7 P E Aftertreatment #1 Outlet NOx : Not Responding Properly ECM 3226 7 P L Aftertreatment #1 Outlet NOx :

Not Responding Properly ECM 3226 7 S E NOx sensor downstream, internal fault ECM 3226 7 S L NOx sensor downstream, internal fault ECM 3226 9 C E Aftertreatment 1 Outlet NOx Sensor - Abnormal update rate ECM 3226 9 C L Aftertreatment 1 Outlet NOx Sensor - Abnormal update rate ECM 3226 9 S E NOx sensor downstream of the SCR catalytic converter ECM 3226 9 S L NOx sensor downstream of the SCR catalytic converter ECM 3226 10 S F NOx sensor downstream, stuck ECM 3226 17 S F NOx sensor downstream, low signal ECM 3226 18 S F NOx sensor downstream, too low value ECM 3226 19 S F NOx sensor downstream of the cat- alytic converter ECM 3226 2 S F Aftertreatment Outlet NOx ECM 3226 20 S F NOx sensor downstream, not plausi- ble ECM 3226 13 C E Aftertreatment 1 Outlet NOx Sensor - Out of Calibration ECM 3226 13 C L Aftertreatment 1 Outlet NOx Sensor - Out of Calibration ECM 3226 3 S F Aftertreatment Outlet NOx ECM 3226 4 S F NOx sensor downstream, internal fault or open circuit ECM 3226 5 S F NOx sensor downstream, open cir- cuit ECM 3226 6 S F Aftertreatment Outlet NOx ECM 3226 7 S F NOx sensor downstream, internal fault ECM 3226 21 C E Aftertreatment 1 Outlet NOx Sensor - Data not Rational - Drifted High ECM 3226 8 S F NOx sensor downstream error via CAN ECM 3226 21 C L Aftertreatment 1 Outlet NOx Sensor - Data not Rational - Drifted High ECM 3226 9 S F NOx sensor downstream of the SCR catalytic converter ECM 3226 8 S E NLev.4 sensor downstream error via CAN continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3226 8 S L NLev.4 sensor downstream error via CAN ECM 3227 9 C F Aftertreatment Outlet Oxygen Sen- sor Circuit - Abnormal update rate ECM 3227 16 P E Aftertreatment #1 Outlet O2 : High - moderate severity (2) ECM 3227 16 P L Aftertreatment #1 Outlet O2 :

High - moderate severity (2) ECM 3227 20 C E Aftertreatment Outlet Oxygen - Data Not Rational - Drifted High ECM 3227 20 C L Aftertreatment Outlet Oxygen - Data Not Rational - Drifted High ECM 3227 21 C E Aftertreatment Outlet Oxygen - Data Not Rational - Drifted Low ECM 3227 21 C L Aftertreatment Outlet Oxygen - Data Not Rational - Drifted Low ECM 3227 9 C E Aftertreatment Outlet Oxygen Sen- sor Circuit - Abnormal update rate ECM 3227 9 C L Aftertreatment Outlet Oxygen Sen- sor Circuit - Abnormal update rate ECM 3228 2 C F Aftertreatment 1 Outlet NOx Sensor Power Supply - Data erratic, inter- mittent or incorrect ECM 3228 2 C E Aftertreatment 1 Outlet NOx Sensor Power Supply - Data erratic, inter- mittent or incorrect ECM 3228 2 C L Aftertreatment 1 Outlet NOx Sensor Power Supply - Data erratic, inter- mittent or incorrect ECM 3234 2 C F Aftertreatment Outlet NOx Sensor - Data Erratic, Intermittent, or Incor- rect.

An incorrect NOx sensor read- ing has been detected by the after- treatment outlet NOx sensor. ECM 3234 4 C F Aftertreatment NOx Sensor - Volt- age Below Normal, or Shorted to Low Source. Out-of-range battery voltage has been detected by the af- tertreatment outlet NOx sensor. ECM 3234 9 C F Aftertreatment Outlet NOx Sensor - Abnormal Update Rate. No commu- nications or valid data transfer rate detected on the J1939 datalink be- tween the ECM and the aftertreat- ment outlet NOx sensor. ECM 3241 19 S F CAN Error from Exhaust Tempera- ture Sensors ECM 3241 10 C F ECM 3241 2 C F Exhaust Gas Temperature 1 Data Erratic, Intermittent, or Incorrect.

The exhaust gas temperature #1 sensor is not changing with engine operating conditions. ECM 3241 3 C F Exhaust Gas Temperature 1 Circuit Voltage Above Normal, or Shorted to Low Source. High signal voltage detected at the catalyst inlet temper- ature sensor circuit ECM 3241 31 C F Catalyst Inlet Temperature Sensor Swapped with Outlet Condition Ex- ists. The inlet and outlet catalyst temperature sensor connections are swapped. ECM 3241 4 C F Exhaust Gas Temperature 1 Circuit Voltage Below Normal, or Shorted to Low Source. Low signal voltage de- tected at the catalyst inlet tempera- ture sensor circuit.

ECM 3241 10 S E Upstream catalyst temperature sen- sor not plausible, not plausible ECM 3241 10 S L Upstream catalyst temperature sen- sor not plausible, not plausible ECM 3241 2 S E Upstream catalyst temperature sen- sor not plausible, not plausible continued..........