49 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3241 2 S L Upstream catalyst temperature sen- sor not plausible, not plausible ECM 3241 4 S E Upstream catalyst temperature sen- sor not plausible, short circuit ECM 3241 4 S L Upstream catalyst temperature sen- sor not plausible, short circuit ECM 3241 5 S E Upstream catalyst temperature sen- sor not plausible, open circuit ECM 3241 5 S L Upstream catalyst temperature sen- sor not plausible, open circuit ECM 3241 8 S E Upstream catalyst temperature sen- sor not plausible, to high ECM 3241 8 S L Upstream catalyst temperature sen- sor not plausible, to high ECM 3241 10 S F Upstream catalyst temperature sen- sor not plausible, not plausible ECM 3241 11 S F Aftertreatment Exhaust Gas Tem- perature ECM 3241 11 S E The exhaust gas temperature sen- sor upstream of the oxidation cata- lytic converter indicates incorrect values.
ECM 3241 12 S F Aftertreatment Exhaust Gas Tem- perature ECM 3241 11 S L The exhaust gas temperature sen- sor upstream of the oxidation cata- lytic converter indicates incorrect values. ECM 3241 15 C F Exhaust Gas Temperature 1 Data Valid but Above Normal Operational Range Least Severe Level. High catalyst inlet temperature has been detected. ECM 3241 12 S E The exhaust gas temperature sen- sor upstream of the oxidation cata- lytic converter indicates incorrect values. ECM 3241 16 S F Upstream catalyst temperature too high ECM 3241 12 S L The exhaust gas temperature sen- sor upstream of the oxidation cata- lytic converter indicates incorrect values.
ECM 3241 16 S E Upstream catalyst temperature too high ECM 3241 18 S F Upstream catalyst temperature sen- sor not plausible, to low ECM 3241 16 S L Upstream catalyst temperature too high ECM 3241 18 S E Upstream catalyst temperature sen- sor not plausible, to low ECM 3241 18 S L Upstream catalyst temperature sen- sor not plausible, to low ECM 3241 2 S F Upstream catalyst temperature sen- sor not plausible, not plausible ECM 3241 19 S E CAN Error from Exhaust Tempera- ture Sensors ECM 3241 3 S F Upstream catalyst temperature sen- sor not plausible, to high ECM 3241 19 S L CAN Error from Exhaust Tempera- ture Sensors ECM 3241 4 S F Upstream catalyst temperature sen- sor not plausible, short circuit ECM 3241 5 S F Upstream catalyst temperature sen- sor not plausible, open circuit ECM 3241 3 S E Upstream catalyst temperature sen- sor not plausible, to high ECM 3241 6 S F Aftertreatment Exhaust Gas Tem- perature continued..........
...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3241 3 S L Upstream catalyst temperature sen- sor not plausible, to high ECM 3241 8 S F Upstream catalyst temperature sen- sor not plausible, to high ECM 3241 6 S E The exhaust gas temperature sen- sor upstream of the oxidation cata- lytic converter indicates incorrect values. ECM 3241 6 S L The exhaust gas temperature sen- sor upstream of the oxidation cata- lytic converter indicates incorrect values. ECM 3242 0 P E Particulate Trap Intake Gas Temper- ature : High - most severe (3) ECM 3242 0 P L Particulate Trap Intake Gas Temper- ature :
High - most severe (3) ECM 3242 0 S E Upstream DPF temperature sensor, too high ECM 3242 0 S L Upstream DPF temperature sensor, too high ECM 3242 16 C F Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But Above Normal Operating Range ECM 3242 7 S F Upstream DPF temperature sensor, not plausible ECM 3242 9 S F Upstream DPF temperature sensor, not plausible ECM 3242 0 C E Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data val- id but above normal operation ECM 3242 0 C L Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data val- id but above normal operation ECM 3242 0 Y E DPF inlet temperature sensor error (high temperature) ECM 3242 0 Y L DPF inlet temperature sensor error (high temperature) ECM 3242 15 C F Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But Above Normal Operating Range ECM 3242 3 C F Aftertreatment 1 Diesel Particulate Filter Intake Temperature Sensor Circuit - Voltage above normal, or shorted to high source ECM 3242 4 C F Aftertreatment 1 Diesel Particulate Filter Intake Temperature Sensor Circuit - Voltage below normal, or shorted to low source ECM 3242 15 C E Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But Above Normal Operating Range ECM 3242 15 C L Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But Above Normal Operating Range ECM 3242 16 C E Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But Above Normal Operating Range ECM 3242 16 C L Aftertreatment 1 Diesel Particulate Filter Intake Temperature - Data Valid But Above Normal Operating Range ECM 3242 16 S E Upstream DPF temperature too high during regeneration ECM 3242 16 S L Upstream DPF temperature too high during regeneration ECM 3242 18 P E Aftertreatment #1 DPF Intake Gas Temperature :
Low - moderate se- verity (2) continued..........