51 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3246 15 S F Downstream DPF temperature too high during normal condition ECM 3246 16 C F Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Val- id But Above Normal Operating Range ECM 3246 9 S F Downstream exhaust temperature sensor, not plausible ECM 3246 0 C E Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data val- id but above normal operation ECM 3246 0 C L Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data val- id but above normal operation ECM 3246 15 C F Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Val- id But Above Normal Operating Range ECM 3246 2 C F Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data er- ratic, intermittent or incorrect ECM 3246 3 C F Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit - Voltage above normal, or shorted to high source ECM 3246 4 C F Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit - Voltage below normal, or shorted to low source ECM 3246 15 C E Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Val- id But Above Normal Operating Range ECM 3246 15 C L Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Val- id But Above Normal Operating Range ECM 3246 15 S E Downstream DPF temperature too high during normal condition ECM 3246 15 S L Downstream DPF temperature too high during normal condition ECM 3246 16 C E Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Val- id But Above Normal Operating Range ECM 3246 16 C L Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data Val- id But Above Normal Operating Range ECM 3246 16 S E Downstream DPF temperature too high during regeneration ECM 3246 16 S L Downstream DPF temperature too high during regeneration ECM 3246 19 S E The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values.

ECM 3246 19 S L The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values.

ECM 3246 2 C E Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data er- ratic, intermittent or incorrect ECM 3246 2 C L Aftertreatment 1 Diesel Particulate Filter Outlet Temperature - Data er- ratic, intermittent or incorrect ECM 3246 3 C E Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit - Voltage above normal, or shorted to high source ECM 3246 3 C L Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit - Voltage above normal, or shorted to high source ECM 3246 3 S E Exhaust temperature sensor after SCR catalytic converter, short circuit continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3246 3 S L Exhaust temperature sensor after SCR catalytic converter, short circuit ECM 3246 4 C E Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit - Voltage below normal, or shorted to low source ECM 3246 4 C L Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit - Voltage below normal, or shorted to low source ECM 3246 4 S E Exhaust temperature sensor after SCR catalytic converter, open circuit ECM 3246 4 S L Exhaust temperature sensor after SCR catalytic converter, open circuit ECM 3246 11 S F Aftertreatment Diesel Particulate Fil- ter Outlet Gas Temperature ECM 3246 11 S E The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values.

ECM 3246 12 S F Aftertreatment Diesel Particulate Fil- ter Outlet Gas Temperature ECM 3246 11 S L The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values. ECM 3246 16 S F Downstream DPF temperature too high during regeneration ECM 3246 19 S F Aftertreatment Diesel Particulate Fil- ter Outlet Gas Temperature ECM 3246 12 S E The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values. ECM 3246 2 S F Downstream DPF temperature sen- sor error ECM 3246 12 S L The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values.

ECM 3246 3 S F Exhaust temperature sensor after SCR catalytic converter, short circuit ECM 3246 4 S F Exhaust temperature sensor after SCR catalytic converter, open circuit ECM 3246 2 S E Downstream DPF temperature sen- sor error ECM 3246 5 S F Aftertreatment Diesel Particulate Fil- ter Outlet Gas Temperature ECM 3246 2 S L Downstream DPF temperature sen- sor error ECM 3246 5 S E The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values. ECM 3246 6 S F Aftertreatment Diesel Particulate Fil- ter Outlet Gas Temperature ECM 3246 5 S L The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values.

ECM 3246 6 S E The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values. ECM 3246 6 S L The exhaust gas temperature sen- sor downstream of the particulate fil- ter indicates incorrect values. ECM 3246 9 S E Downstream exhaust temperature sensor, not plausible ECM 3246 9 S L Downstream exhaust temperature sensor, not plausible ECM 3249 10 C F Exhaust Gas Temperature 2 Abnor- mal Rate of Change. The catalyst outlet temperature sensor is not re- sponding to a change in engine op- erating conditions. ECM 3249 17 C F Aftertreatment Exhaust Gas Tem- perature 2 - Data Valid But Below continued..........