Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

52 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description Normal Operating Range - Least Severe Level ECM 3249 18 C F Aftertreatment Exhaust Gas Tem- perature 2 - Data Valid But Below Normal Operating Range - Moder- ately Severe Level ECM 3249 2 C F Exhaust Gas Temperature 2 Data Erratic, Intermittent, or Incorrect. The exhaust gas temperature #2 sensor is not changing with engine operating conditions. ECM 3249 3 C F Exhaust Gas Temperature 2 Circuit Voltage Above Normal, or Shorted to Low Source. High signal voltage detected at the catalyst outlet tem- perature sensor circuit.

ECM 3249 4 C F Exhaust Gas Temperature 2 Circuit Voltage Below Normal, or Shorted to Low Source. Low signal voltage de- tected at the catalyst exhaust tem- perature sensor circuit. ECM 3249 18 C E Aftertreatment Exhaust Gas Tem- perature 2 - Data Valid But Below Normal Operating Range - Moder- ately Severe Level ECM 3249 18 C L Aftertreatment Exhaust Gas Tem- perature 2 - Data Valid But Below Normal Operating Range - Moder- ately Severe Level ECM 3249 3 S E Fault on the exhaust gas tempera- ture sensor upstream of the SCR catalytic converter. ECM 3249 3 S L Fault on the exhaust gas tempera- ture sensor upstream of the SCR catalytic converter.

ECM 3249 4 S E Fault on the exhaust gas tempera- ture sensor upstream of the SCR catalytic converter. ECM 3249 4 S L Fault on the exhaust gas tempera- ture sensor upstream of the SCR catalytic converter.

ECM 3249 3 S F Aftertreatment Exhaust Gas Tem- perature ECM 3249 4 S F Aftertreatment Exhaust Gas Tem- perature ECM 3249 17 C E Aftertreatment Exhaust Gas Tem- perature 2 - Data Valid But Below Normal Operating Range - Least Severe Level ECM 3249 17 C L Aftertreatment Exhaust Gas Tem- perature 2 - Data Valid But Below Normal Operating Range - Least Severe Level MCU 325 4 * F Fuel Warmer Relay Circuit - Voltage Below Normal, or Shorted to Low Source (or Open Circuit) MCU 325 3 * E Fuel Warmer Relay-Voltage Above Normal, Or Shorted To High Source MCU 325 3 * L Fuel Warmer Relay-Voltage Above Normal, Or Shorted To High Source MCU 325 4 * E Fuel Warmer Relay-Voltage Below Normal, Or Shorted To Low Source MCU 325 4 * L Fuel Warmer Relay-Voltage Below Normal, Or Shorted To Low Source MCU 325 6 * E Fuel Warmer Relay-Current Above Normal Or Grounded Circuit MCU 325 6 * L Fuel Warmer Relay-Current Above Normal Or Grounded Circuit MCU 325 6 * F Fuel Warmer Relay Circuit .

Current Above Normal ECM 3250 0 Y E DPF intermediate temperature sen- sor temperature rise error (post-in- jection failure) continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3250 0 Y L DPF intermediate temperature sen- sor temperature rise error (post-in- jection failure) ECM 3250 1 Y E DPF intermediate temperature sen- sor temperature too low ECM 3250 1 Y L DPF intermediate temperature sen- sor temperature too low ECM 3250 3 Y E DPF intermediate temperature sen- sor error (voltage high) ECM 3250 3 Y L DPF intermediate temperature sen- sor error (voltage high) ECM 3250 4 Y E DPF intermediate temperature sen- sor error (voltage low) ECM 3250 4 Y L DPF intermediate temperature sen- sor error (voltage low) ECM 3251 0 P E Particulate Trap Differential Pres- sure :

High - most severe (3) ECM 3251 0 P L Particulate Trap Differential Pres- sure :

High - most severe (3) ECM 3251 0 C F Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data valid but above normal Operating Range ECM 3251 0 C E Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data valid but above normal Operating Range ECM 3251 0 C L Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data valid but above normal Operating Range ECM 3251 0 Y E DPF differential pressure sensor dif- ferential pressure rise error ECM 3251 0 Y L DPF differential pressure sensor dif- ferential pressure rise error ECM 3251 13 Y E DPF differential pressure sensor er- ror (abnormal learning value) ECM 3251 13 Y L DPF differential pressure sensor er- ror (abnormal learning value) ECM 3251 7 P E Particulate Trap Differential Pres- sure :

Not Responding Properly ECM 3251 7 P L Particulate Trap Differential Pres- sure :

Not Responding Properly ECM 3251 7 S E Differential pressure sensor over particulate filter, faulty ECM 3251 7 S L Differential pressure sensor over particulate filter, faulty ECM 3251 15 C F Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data valid but above normal Operating Range ECM 3251 16 C F Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data Valid But Above Normal Operating Range ECM 3251 2 C F Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor - Data erratic, intermittent or incorrect ECM 3251 3 C F Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor Cir- cuit - Voltage above normal ECM 3251 4 C F Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor Cir- cuit - Voltage below normal ECM 3251 16 C E Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data Valid But Above Normal Operating Range ECM 3251 16 C L Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data Valid But Above Normal Operating Range ECM 3251 16 P E Particulate Trap Differential Pres- sure :

High - moderate severity (2) ㅡ ECM 3251 16 P L Particulate Trap Differential Pres- sure : High - moderate severity (2) ㅡ continued..........