Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

53 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3251 18 P E Particulate Trap Differential Pres- sure : Low - moderate severity (2) ECM 3251 18 P L Particulate Trap Differential Pres- sure : Low - moderate severity (2) ECM 3251 2 S E Particulate filter is missing ECM 3251 2 S L Particulate filter is missing ECM 3251 3 C E Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor Cir- cuit - Voltage above normal ECM 3251 3 C L Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor Cir- cuit - Voltage above normal ECM 3251 3 P E Particulate Trap Differential Pres- sure :

Voltage Above Normal ECM 3251 3 P L Particulate Trap Differential Pres- sure : Voltage Above Normal ECM 3251 3 S E Fault in the particulate filter differen- tial pressure sensor ECM 3251 3 S L Fault in the particulate filter differen- tial pressure sensor ECM 3251 3 Y E DPF differential pressure sensor er- ror (voltage high) ECM 3251 3 Y L DPF differential pressure sensor er- ror (voltage high) ECM 3251 4 C E Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor Cir- cuit - Voltage below normal ECM 3251 4 C L Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor Cir- cuit - Voltage below normal ECM 3251 4 P E Particulate Trap Differential Pres- sure :

Voltage Below Normal ECM 3251 4 P L Particulate Trap Differential Pres- sure : Voltage Below Normal ECM 3251 4 S E Fault in the particulate filter differen- tial pressure sensor ECM 3251 4 S L Fault in the particulate filter differen- tial pressure sensor ECM 3251 4 Y E DPF differential pressure sensor er- ror (voltage low) ECM 3251 4 Y L DPF differential pressure sensor er- ror (voltage low) ECM 3251 10 C E Aftertreatment 1 Diesel Particulate Filter Differential Pressure - Abnor- mal Rate of Change ECM 3251 10 C L Aftertreatment 1 Diesel Particulate Filter Differential Pressure - Abnor- mal Rate of Change ECM 3251 10 P E Particulate Trap Differential Pres- sure :

Abnormal Rate of Change ECM 3251 10 P L Particulate Trap Differential Pres- sure : Abnormal Rate of Change ECM 3251 15 C E Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data valid but above normal Operating Range ECM 3251 15 C L Aftertreatment Diesel Particulate Fil- ter Differential Pressure - Data valid but above normal Operating Range ECM 3251 17 P E Particulate Trap Differential Pres- sure : Low - least severe (1) ECM 3251 17 P L Particulate Trap Differential Pres- sure :

Low - least severe (1) ECM 3251 2 S F Particulate filter is missing ECM 3251 3 S F Fault in the filter system ECM 3251 4 S F Fault in the filter system ECM 3251 7 S F Differential pressure sensor over particulate filter, faulty continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3251 2 C E Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor - Data erratic, intermittent or incorrect ECM 3251 8 S F Differential pressure sensor not plausible ECM 3251 2 C L Aftertreatment Diesel Particulate Fil- ter Differential Pressure Sensor - Data erratic, intermittent or incorrect ECM 3251 8 S E Differential pressure sensor not plausible ECM 3251 9 S F Differential pressure sensor over particulate filter, not plausible ECM 3251 8 S L Differential pressure sensor not plausible ECM 3251 9 S E Differential pressure sensor over particulate filter, not plausible ECM 3251 9 S L Differential pressure sensor over particulate filter, not plausible ECM 3255 9 C F Aftertreatment 2 Intake Nox Sensor - Abnormal update rate ECM 3255 9 C E Aftertreatment 2 Intake NOx Sensor - Abnormal update rate ECM 3255 9 C L Aftertreatment 2 Intake NOx Sensor - Abnormal update rate ECM 3265 9 C F Aftertreatment 2 Outlet NOx - Ab- normal Update Rate ECM 3265 9 C E Aftertreatment 2 Outlet NOx - Ab- normal Update Rate ECM 3265 9 C L Aftertreatment 2 Outlet NOx - Ab- normal Update Rate MCU 327 4 * E Anti-Restart Relay-Voltage Below Normal, Or Shorted To Low Source MCU 327 4 * L Anti-Restart Relay-Voltage Below Normal, Or Shorted To Low Source MCU 327 6 * E Anti-Restart Relay-Current Above Normal Or Grounded Circuit MCU 327 6 * L Anti-Restart Relay-Current Above Normal Or Grounded Circuit MCU 327 4 * F Anti-Restart Relay Circuit - Voltage Below Normal, or Shorted to Low Source (or Open Circuit) MCU 327 6 * F Anti-Restart Relay Circuit .

Current Above Normal ECM 3275 19 S E The EEC control unit for exhaust gas aftertreatment has lost contact with the exhaust gas temperature sensor upstream of the SCR catalyt- ic converter. ECM 3275 19 S L The EEC control unit for exhaust gas aftertreatment has lost contact with the exhaust gas temperature sensor upstream of the SCR catalyt- ic converter.

ECM 3275 0 S F Exhaust gas temperature upstream ECM 3275 1 S F Exhaust gas temperature upstream ECM 3275 11 S F Exhaust gas temperature upstream ECM 3275 12 S F Exhaust gas temperature upstream ECM 3275 19 S F EEC unit has no contact with sen- sors ECM 3275 2 S F Exhaust gas temperature upstream ECM 3275 3 S F Exhaust gas temperature upstream ECM 3275 4 S F Exhaust gas temperature upstream ECM 3275 5 S F Exhaust gas temperature upstream ECM 3275 6 S F Exhaust gas temperature upstream ECM 3275 9 S F EEC unit has no contact with sen- sors ECM 3279 19 S E The EEC control unit for exhaust gas aftertreatment has lost contact continued..........