Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

55 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3360 16 S L SCR main unit, internal supply volt- age high ECM 3360 19 S E SCR main unit, communication error ECM 3360 19 S L SCR main unit, communication error ECM 3360 3 P E Aftertreatment #1 DEF Controller : Voltage Above Normal ECM 3360 3 P L Aftertreatment #1 DEF Controller :

Voltage Above Normal ECM 3360 3 S E SCR main unit, ventilation valve test, short to battery ECM 3360 3 S L SCR main unit, ventilation valve test, short to battery ECM 3360 5 S E SCR main unit, ventilation valve test, open load ECM 3360 5 S L SCR main unit, ventilation valve test, open load ECM 3360 6 S E SCR main unit, system voltage error ECM 3360 6 S L SCR main unit, system voltage error ECM 3360 9 P E Aftertreatment #1 DEF Controller : Abnormal Update Rate ECM 3360 9 P L Aftertreatment #1 DEF Controller :

Abnormal Update Rate ECM 3360 9 S E EEC3 has demanded SCR Major functional failure reductant dosing stopped actions ECM 3360 9 S L EEC3 has demanded SCR Major functional failure reductant dosing stopped actions ECM 3360 0 S F SCR system adaptation have reached max values ECM 3360 1 S F SCR system adaptation have reached min values ECM 3360 10 S F EEC3 System has demanded "SCR minor functional failure" actions ECM 3360 12 S F SCR main unit, error ECM 3360 16 S F SCR main unit, internal supply volt- age high ECM 3360 19 S F SCR main unit, communication error ECM 3360 12 S E SCR main unit, error ECM 3360 2 S F EEC3 System has demanded "SCR Hazardous major functional failure" actions ECM 3360 12 S L SCR main unit, error ECM 3360 3 S F SCR main unit, ventilation valve test, short to battery ECM 3360 2 S E EEC3 System has demanded SCR Hazardous major functional failure actions ECM 3360 2 S L EEC3 System has demanded SCR Hazardous major functional failure actions ECM 3360 4 P E Aftertreatment #1 DEF Controller :

Voltage Below Normal ECM 3360 4 S F SCR main unit, internal supply volt- age low ECM 3360 4 P L Aftertreatment #1 DEF Controller : Voltage Below Normal ECM 3360 5 S F SCR main unit, ventilation valve test, open load ECM 3360 4 S E SCR main unit, internal supply volt- age low ECM 3360 7 S F SCR main unit, ignition switch plau- sible error ECM 3360 4 S L SCR main unit, internal supply volt- age low continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3360 9 S F EEC3 has demanded "SCR Major functional failure reductant dosing stopped" actions ECM 3360 7 S E SCR main unit, ignition switch plau- sible error ECM 3360 7 S L SCR main unit, ignition switch plau- sible error ECM 3361 1 C F ECM 3361 12 C F Catalyst Dosing Control Unit Bad In- telligent Device or Component. An internal error has been detected in the catalyst dosing control unit.

ECM 3361 2 C F Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit Temperature - Data erratic, intermittent or incorrect ECM 3361 3 C F Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit - Voltage above nor- mal, or shorted to high source ECM 3361 4 C F Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit - Voltage below nor- mal, or shorted to low source ECM 3361 9 C F Dosing Control Unit Data Link Ab- normal Update Rate. Data Link com- munications between the ECM and the Dosing Control Unit have been interrupted.

ECM 3361 3 C E Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit - Voltage above nor- mal, or shorted to high source ECM 3361 3 C L Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit - Voltage above nor- mal, or shorted to high source ECM 3361 3 S E SCR reductant dosing valve, short circuit to battery ECM 3361 3 S L SCR reductant dosing valve, short circuit to battery ECM 3361 4 C E Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit - Voltage below nor- mal, or shorted to low source ECM 3361 4 C L Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit - Voltage below nor- mal, or shorted to low source ECM 3361 4 S E Fault in reductant doser injection valve.

ECM 3361 4 S L Fault in reductant doser injection valve. ECM 3361 5 P E Aftertreatment #1 DEF Dosing Unit : Current Below Normal ECM 3361 5 P L Aftertreatment #1 DEF Dosing Unit : Current Below Normal ECM 3361 5 S E SCR reductant dosing valve, open circuit ECM 3361 5 S L SCR reductant dosing valve, open circuit ECM 3361 6 P E Aftertreatment #1 DEF Dosing Unit : Current Above Normal ECM 3361 6 P L Aftertreatment #1 DEF Dosing Unit : Current Above Normal ECM 3361 6 S E Fault in reductant doser injection valve. ECM 3361 6 S L Fault in reductant doser injection valve.

ECM 3361 10 S F SCR main unit, reductant pressure not plausible ECM 3361 10 S E SCR main unit, reductant pressure not plausible ECM 3361 10 S L SCR main unit, reductant pressure not plausible ECM 3361 2 C E Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit Temperature - Data erratic, intermittent or incorrect continued..........