Cummins — Cummins Engine Error Codes Manual for Hyundai Construction Equipment

56 4 SPN 3~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3361 2 S F Reductant doser injection valve ECM 3361 2 C L Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit Temperature - Data erratic, intermittent or incorrect ECM 3361 3 S F SCR reductant dosing valve, short circuit to battery ECM 3361 4 S F Reductant doser injection valve ECM 3361 5 S F SCR reductant dosing valve, open circuit ECM 3361 6 S F Reductant doser injection valve ECM 3361 2 S E Fault in reductant doser injection valve. ECM 3361 2 S L Fault in reductant doser injection valve.

ECM 3362 31 C F Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit Input Lines - Condi- tion Exists ECM 3362 0 S E The reductant pressure has been above the permitted level. ECM 3362 0 S L The reductant pressure has been above the permitted level. ECM 3362 1 S E Required reductant pressure cannot be reached. ECM 3362 1 S L Required reductant pressure cannot be reached.

ECM 3362 2 S E SCR reductant pressure, error ECM 3362 2 S L SCR reductant pressure, error ECM 3362 0 S F Reductant pressure ECM 3362 1 S F Reductant pressure ECM 3362 2 S F SCR reductant pressure, error ECM 3362 31 C E Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit Input Lines - Condi- tion Exists ECM 3362 31 C L Aftertreatment 1 Diesel Exhaust Flu- id Dosing Unit Input Lines - Condi- tion Exists ECM 3363 16 C F Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Data Valid But Above Normal Operating Range - Moderately Severe Level ECM 3363 18 C F Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Data Valid But Be- low Normal Operating Range - Mod- erately Severe Level ECM 3363 3 C F Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Voltage above nor- mal, or shorted to high source ECM 3363 4 C F Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Voltage below nor- mal, or shorted to low source ECM 3363 7 C F Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Mechanical system not responding or out of adjustment ECM 3363 0 S E SCR main unit, reductant heater, cir- cuit high ECM 3363 0 S L SCR main unit, reductant heater, cir- cuit high ECM 3363 16 C E Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Data Valid But Above Normal Operating Range - Moderately Severe Level ECM 3363 16 C L Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Data Valid But Above Normal Operating Range - Moderately Severe Level ECM 3363 16 S E SCR main unit, high temperature high limit exceeded ECM 3363 16 S L SCR main unit, high temperature high limit exceeded continued..........

...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 3363 17 S E SCR reductant tank temperatur too low ECM 3363 17 S L SCR reductant tank temperatur too low ECM 3363 18 C E Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Data Valid But Be- low Normal Operating Range - Mod- erately Severe Level ECM 3363 18 C L Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Data Valid But Be- low Normal Operating Range - Mod- erately Severe Level ECM 3363 18 S E SCR main unit, low temperature limit exceeded ECM 3363 18 S L SCR main unit, low temperature limit exceeded ECM 3363 2 S E SCR main unit, reductant heater, open load ECM 3363 2 S L SCR main unit, reductant heater, open load ECM 3363 3 C E Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Voltage above nor- mal, or shorted to high source ECM 3363 3 C L Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Voltage above nor- mal, or shorted to high source ECM 3363 3 S E SCR main unit, internal heating pump, short circuit to battery ECM 3363 3 S L SCR main unit, internal heating pump, short circuit to battery ECM 3363 4 C E Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Voltage below nor- mal, or shorted to low source ECM 3363 4 C L Aftertreatment 1 Diesel Exhaust Flu- id Tank Heater - Voltage below nor- mal, or shorted to low source ECM 3363 4 S E SCR main unit, reductant tempera- ture sensor circuit low ECM 3363 4 S L SCR main unit, reductant tempera- ture sensor circuit low ECM 3363 5 P E Aftertreatment #1 DEF Tank Heat- er :

Current Below Normal ECM 3363 5 P L Aftertreatment #1 DEF Tank Heat- er : Current Below Normal ECM 3363 5 S E SCR main unit, internal heating pump, open load ECM 3363 5 S L SCR main unit, internal heating pump, open load ECM 3363 6 P E Aftertreatment #1 DEF Tank Heat- er : Current Above Normal ECM 3363 6 P L Aftertreatment #1 DEF Tank Heat- er : Current Above Normal ECM 3363 6 S E The heater of the reductant doser has consumed more power than permitted. ECM 3363 6 S L The heater of the reductant doser has consumed more power than permitted.

ECM 3363 8 S E SCR main unit, reductant heater, cir- cuit performance ECM 3363 8 S L SCR main unit, reductant heater, cir- cuit performance ECM 3363 0 S F SCR main unit, reductant heater, cir- cuit high ECM 3363 15 S F SCR reagent tank temperature too high ECM 3363 16 S F SCR main unit, high temperature high limit exceeded ECM 3363 17 S F SCR reductant tank temperatur too low continued..........