82 6 SPN 5~ ...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 52 0 C E Coolant Temperature 2 - Data Valid but Above Normal Operational Range - Most Severe Level ECM 52 0 C L Coolant Temperature 2 - Data Valid but Above Normal Operational Range - Most Severe Level ECM 52 16 C E Coolant Temperature 2 - Data Valid but Above Normal Operational Range - Moderately Severe Level ECM 52 16 C L Coolant Temperature 2 - Data Valid but Above Normal Operational Range - Moderately Severe Level ECM 52 3 C E Coolant Temperature 2 Sensor Cir- cuit - Voltage Above Normal, or Shorted to High Source ECM 52 3 C L Coolant Temperature 2 Sensor Cir- cuit - Voltage Above Normal, or Shorted to High Source ECM 52 4 C E Coolant Temperature 2 Sensor Cir- cuit - Voltage Below Normal, or Shor- ted to Low Source ECM 52 4 C L Coolant Temperature 2 Sensor Cir- cuit - Voltage Below Normal, or Shor- ted to Low Source TCU 52 * * L EAMODUL1 TIMEOUT TCU 52 * * F EAMODUL1 TIMEOUT ECM 52 0 C F Coolant Temperature :
Coolant Tem- perature 2 - Data Valid but Above Normal Operational Range - Most Severe Level ECM 52 16 C F Coolant Temperature : Coolant Tem- perature 2 - Data Valid but Above Normal Operational Range - Moder- ately Severe Level ECM 52 3 C F Coolant Temperature : Coolant Tem- perature 2 Sensor Circuit - Voltage Above Normal, or Shorted to High Source ECM 52 4 C F Coolant Temperature : Coolant Tem- perature 2 Sensor Circuit - Voltage Below Normal, or Shorted to Low Source MCU 520 3 * E Ram Lock Status ? Indicator Lamp- Voltage Above Normal, Or Shorted To High Source MCU 520 3 * L Ram Lock Status ? Indicator Lamp- Voltage Above Normal, Or Shorted To High Source MCU 520 4 * E Ram Lock Status ?
Indicator Lamp- Voltage Below Normal, Or Shorted To Low Source MCU 520 4 * L Ram Lock Status ? Indicator Lamp- Voltage Below Normal, Or Shorted To Low Source ECM 5201 99 3 C E Cruise Control (Resistive) Signal Cir- cuit - Voltage above normal, or shor- ted to high source ECM 5201 99 3 C L Cruise Control (Resistive) Signal Cir- cuit - Voltage above normal, or shor- ted to high source ECM 5201 99 4 C E Cruise Control (Resistive) Signal Cir- cuit - Voltage below normal, or shor- ted to low source ECM 5201 99 4 C L Cruise Control (Resistive) Signal Cir- cuit - Voltage below normal, or shor- ted to low source ECM 5201 99 3 C F Cruise Control :
Cruise Control (Re- sistive) Signal Circuit - Voltage Above Normal, or Shorted to High Source ECM 5201 99 4 C F Cruise Control : Cruise Control (Re- sistive) Signal Circuit - Voltage Be- low Normal, or Shorted to Low Source continued..........
...........continued TYPE SPN FMI En- gine Ma- chine type Description ECM 5202 86 11 C F Aftertreatment Diesel Oxidation Cat- alyst Temperature Sensor Module - Root Cause Not Known ECM 5202 86 4 C F Aftertreatment Diesel Oxidation Cat- alyst Temperature Sensor Module - Voltage Below Normal or Shorted to Low Source ECM 5203 20 7 C F Crankcase Depression Valve - Me- chanical system not responding or out of adjustment ECM 5203 20 7 C E Crankcase Depression Valve - Me- chanical system not responding or out of adjustment ECM 5203 20 7 C L Crankcase Depression Valve - Me- chanical system not responding or out of adjustment ECM 5203 32 3 C F Cruise Control (Resistive) #2 Signal Circuit - Voltage above normal, or shorted to high source ECM 5203 32 4 C F Cruise Control (Resistive) #2 Signal Circuit - Voltage below normal, or shorted to low source ECM 5203 32 3 C E Cruise Control (Resistive) #2 Signal Circuit - Voltage above normal, or shorted to high source ECM 5203 32 3 C L Cruise Control (Resistive) #2 Signal Circuit - Voltage above normal, or shorted to high source ECM 5203 32 4 C E Cruise Control (Resistive) #2 Signal Circuit - Voltage below normal, or shorted to low source ECM 5203 32 4 C L Cruise Control (Resistive) #2 Signal Circuit - Voltage below normal, or shorted to low source ECM 5204 35 12 C F Glow Plug Module - Bad intelligent device or component ECM 5204 35 12 C E Glow Plug Module - Bad intelligent device or component ECM 5204 35 12 C L Glow Plug Module - Bad intelligent device or component ECM 5205 95 2 C F Closed Crankcase Ventilation Sys- tem Pressure - Data erratic, intermit- tent or incorrect ECM 5205 95 3 C F Closed Crankcase Ventilation Sys- tem Pressure Sensor - Voltage Above Normal, or Shorted to High Source ECM 5205 95 4 C F Closed Crankcase Ventilation Sys- tem Pressure Sensor - Voltage be- low normal, or shorted to low source ECM 5205 95 3 C E Closed Crankcase Ventilation Sys- tem Pressure Sensor - Voltage Above Normal, or Shorted to High Source ECM 5205 95 3 C L Closed Crankcase Ventilation Sys- tem Pressure Sensor - Voltage Above Normal, or Shorted to High Source ECM 5205 95 4 C E Closed Crankcase Ventilation Sys- tem Pressure Sensor - Voltage be- low normal, or shorted to low source ECM 5205 95 4 C L Closed Crankcase Ventilation Sys- tem Pressure Sensor - Voltage be- low normal, or shorted to low source ECM 5205 95 2 C E Closed Crankcase Ventilation Sys- tem Pressure - Data erratic, intermit- tent or incorrect ECM 5205 95 2 C L Closed Crankcase Ventilation Sys- tem Pressure - Data erratic, intermit- tent or incorrect ECM 5206 68 31 C F Aftertreatment 1 Outlet NOx Sensor Closed Loop Operation - Condition Exists continued..........