www.WorkshopManuals.co.uk Starter Motor Starting Circuit Test Test 3 Before carrying out the voltmeter tests, check the battery condition (see Battery Testing) and ensure that all connections are clean and tight. Connect the voltmeter between the solenoid terminal C and a good earth. Minimum permissible reading in 'start' position: 8.0V. To prevent the engine starting during the tests ensure that the engine stop fuse is removed, (refer to fuse identification page). Check the readings in the following sequence using a voltmeter.
Unless otherwise stated, the readings must be taken with the starter switch held in the 'start' position ('HS') and the transmission forward/reverse selector in neutral. C Note: Do not operate the starter motor for more than 20 seconds at one time. Let the starter motor cool for at least two minutes between starts. S151010 Test 1 Connect the voltmeter across the battery terminals. Reading in 'start' position: 10.0V approximately. Minimum permissible reading in 'start' position 9.5V. A low reading probably indicates a fault in the starter motor. Test 3a If the reading is less than specified, connect the voltmeter between the neutral start relay terminal D and earth.
An increase in reading to 8.0V indicates a fault in the wiring from the start relay to the solenoid. N F 810C 600V S151000 R Test 2 Connect the voltmeter between the starter main terminal A and the commutator end bracket B . In the 'start' position, the reading should not be more than 0.5V below the reading obtained in Test 1. Minimum permissible reading in 'start' position 9.0V. 842 004 D E C H + If the reading is within this limit, continue to Test 3. If the reading is outside the limit, proceed to Tests 4 and 5. A - B A B S151030 A215660 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section C Electrics Section C 22 - 1 22 - 1 Service Procedures