JCB — Starting Circuit Test

www.WorkshopManuals.co.uk Starter Motor (cont’d) Starting Circuit Test (cont'd) Test 5 Test 3b Connect the voltmeter between battery positive and the starter main terminal A . With the starter switch 'off', the voltmeter should indicate battery voltage, but it should fall to practically zero when the switch is turned to the 'on' position, maximum permissible reading 0.25V. If the reading between terminal D and earth is below 8.0V, connect the voltmeter between terminal E and earth. An increase in the reading to 8.0V indicates either a faulty start relay or a fault in the feed from the transmission selector switch to the relay solenoid. Check also the solenoid earth connection.

If the reading between E and earth is less than 8.0V, the fault must be in either the starter switch or in the wiring between the solenoid, starter switch, and the start relay. Test 4 Connect the voltmeter between battery negative and starter earth connection B . The reading in the 'start' position should be practically zero, maximum permissible reading 0.25V. A S151050 Test 5a B If the reading is above 0.25V, a high resistance is present in the insulated lead or in the solenoid. Connect the voltmeter between the battery positive and solenoid connection H . If the voltmeter now reads zero with the switch closed, the fault is in the solenoid.

S151040 If the reading is above 0.25V, a high resistance in the earth lead or connections is indicated. H Finally refit the engine stop fuse. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section C Electrics Section C 22 - 2 22 - 2 Service Procedures