JCB — Repair Procedure

www.WorkshopManuals.co.uk Wiring Harness - Repair Procedure (cont'd) e Turn the red ring D to the right (in the direction of the plus sign) in order to turn on the gas. IMPORTANT: Before turning the heater on, make sure that the cartridge is not hotter than the reflector element. This may occur if the cartridge is held in the hand for a long time. The temperature difference between the cartridge and the reflector element may cause long yellow flames to appear on ignition. D S189490/5 f Hold the heater vertically and, using a match or cigarette lighter, light the gas as shown. Note: The fact that the sound of liquid cannot be heard when the cartridge is shaken does not mean it is empty.

No sound will be heard even when the cartridge is full. F Hold the heater vertically for 1 to 2 minutes until the catalytic reaction occurs. This is indicated when the blue flame fades and the ceramic element glows red. Then turn the small ring E until the air holes at F are completely open. The tool is ready for use. E S189490/6 The heater can be used in two modes: g Side wings G down, reflector head completely open. In this mode the infra-red heat waves are dominant (recommended for the light coloured plastic splices). G Side wings G up (see fig at step h ), reflector head opening reduced. In this mode the heating is done only by the hot gas (use for dark coloured plastic splices).

S189490/7 h To switch off the heater, turn the red ring D to the left (in the direction of the minus sign). G D S189490/8 9803/3280 Issue 1 Purchased from www.WorkshopManuals.co.uk Section C Electrics Section C 23 - 3 23 - 3 Service Procedures