JCB — Fault Finding

Fault Finding Introduction The fault finding procedures are given in the form of flow charts. There are a number of charts, each one dedicated to a particular fault. The charts are designed to identify possible causes by performing checks and where applicable, specific tests. Having identified a cause the suggested remedy is given. The charts are designed to identify causes through a process of elimination, starting with the simplest, most easily rectified faults. When fault finding note the following: 1 Make sure that the hydraulic fluid is at the correct working temperature (50 o C, 122 o F).

2 If hydraulic contamination is found be sure to remove ALL debris, and if possible identify its origin. It may be part of a component from elsewhere in the hydraulic circuit. 3 Renew any seals such as ‘O’ rings when re-assembling hydraulic components. Fault Finding Charts: Chart A - No Servo Controls (system fails to operate) Chart B - All Backhoe Services Slow to Operate Chart C - One Backhoe Service fails or is Slow to Operate 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section D Controls Section D 47 - 1 47 - 1 Precision Control (Servo)