Fault Finding Chart A - No Servo Controls (system fails to operate) START Does the system operate if the seat is locked in the opposite facing position? Check that the arm rests are raised forward (i.e. not pushed back) Check the function of the seat mounted proximity switches and condition of associated wiring for damage. Repair or renew as applicable. YES NO Are the servo pressure isolation valve solenoid coils faulty? Renew the solenoid coil(s). YES NO Are the relevant electrical fuses intact? NO Inspect and test all relevant wiring for damage and short circuits. Repair as applicable. Renew the fuses. YES Is the wiring to the servo pressure isolation valve solenoid coils intact?
Repair or renew as applicable. NO YES Renew servo pressure isolation valve cartridge. Refer to Servo Pressure Supply Valve - Dismantling and Assembly. Refer to Electrical Operation - Joystick Controller. A405600 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section D Controls Section D 47 - 2 47 - 2 Precision Control (Servo)