JCB — Main Relief Valve (MRV) - Operation

6 - 12 6 - 12 Circuit Descriptions Main Relief Valve (MRV) - Operation The main relief valve (M.R.V.) 3B, situated in the loader valve block, provides control of both loader and excavator pressures. Component Key: A Main Plunger B Valve Seat C Spring D Chamber E Drilling F Pilot Valve G Spring H Exhaust Gallery 1A Pump Inlet 3B Main Relief Valve 3D Shovel Ram Spool 1 Valve at Rest The illustration 1 shows a loader service selected by spool 3D causing pressure to rise in the service line and back through the loader valve to the pump via line 1A . The service is operating under light load and the pressure is not sufficient to cause any response in the M.R.V.

The main plunger A is held on its seat B by the combined effect of spring C and the pump pressure which enters chamber D through the small drilling E . Pump pressure outside the chamber is not high enough to lift the plunger off its seat. 2 Pilot Valve Opens If, as shown in view 2 , pump pressure rises high enough to force the pilot valve F from its seat (against spring G ), the pressure in chamber D is vented into the exhaust gallery H . Unless the pressure continues to rise, plunger A will remain on its seat.

3 Valve Moves off its seat In view 3 , pump pressure at 1A has risen to the setting of the main relief valve but pressure in chamber D has not risen because the seat orifice of pilot valve F is larger than small drilling E and oil is unable to fill the chamber as quickly as it is being exhausted. Pressure acting on the upper faces of main plunger A is therefore greater than the combined force of spring C and the pressure in chamber D . The plunger then moves off its seat, allowing pressure to be released to the exhaust gallery. As the pump pressure decreases, the pilot valve is able to reseat and pressure in chamber D assists spring C to force the main plunger A back onto its seat.

9803/3280 Issue 1 Purchased from www.WorkshopManuals.co.uk Section E Hydraulics Section E