www.WorkshopManuals.co.uk 3 2 1 9 4 8 6 7 Ј A273670 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 7 - 1 7 - 1 Circuit Descriptions Loader Valve - Variable Flow Operation The loader valve is mounted on the chassis frame, right hand side (when viewed from rear). It is a stack type, directional control valve that is configured for closed centre operation. The valve block comprises two or three service valve sections and a priority steer inlet section. When operated, the designated valve section controls the volume and direction of oil by way of service ports A or B. A constant flow is maintained regardless of changing load pressures.
While the spools are in neutral position, the primary shuttles and secondary shuttles are vented to tank. When a spool is operated, the load pressure sensed at the work port is directed via the primary and secondary shuttles to the hydraulic pump, where the pump subsequently ‘swashes’ to meet this load sense demand. Component Key:
1 Auxiliary (optional) spool 2 Shovel spool 3 Arms lift spool 4 Pump inlet 5 Tank port 6 Load sense port (from valve blocks) 7 Priority load sense port (from steer unit) 8 Priority work port (to steer unit) 9 Load sense carry over port (to backhoe valve) 10 Service ports 11 Auxiliary relief valve (rods side) 12 Auxiliary relief valve (head side) 13 Priority relief valve † † Note: Steer circuit pressure is controlled by a relief valve housed in the hydraulic steer unit (refer to Section H Steering). The priority relief valve housed in the loader valve must be set at 2500 lb/in2, this will ensure it does not interfere with the operation of the relief valve housed in the hydraulic steer unit. !
0 0 0 0 0 0 5