JCB — Variable Flow

9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Hydraulics Section E Section E 15 - 11 15 - 11 Fault Finding PROBLEM: Leaks between sections. POSSIBLE CAUSE: 1) Missing or cut seals. CORRECTIVE ACTION: 1) Disassemble valve stack and check for missing or cut o-rings. PROBLEM: Sticking spool. POSSIBLE CAUSE: 1) Linkage binding. 2) Damaged spool. 3) Uneven torque of tie-rod. 4) Incorrect number of shims on tie-rods. CORRECTIVE ACTION: 1) Check linkage. 2) Remove and inspect spool. 3) Loosen tie-rod bolts, check and re-torque. 4) Disassemble and check that each tie-rod has one shim. PROBLEM: Mechanical detent will not hold. POSSIBLE CAUSE: 1) Broken detent shaft. CORRECTIVE ACTION:

1) Remove detent & inspect. PROBLEM: Electrical detent will not hold. POSSIBLE CAUSE: 1) Current broken. CORRECTIVE ACTION: 1) Check current going into detent. PROBLEM: Poor performance, slow operating speed and/or low maximum stall speed. POSSIBLE CAUSE: 1) Blocked flow regulator spool. CORRECTIVE ACTION: 1) Flow check, remove and clean flow regulator valve, refer to Service Procedures, Variable Flow Pumps - Regulator Valve Adjustment.