www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 15 - 12 15 - 12 Fault Finding Smooth Ride System Fault Probable Cause Action 1 Unable to power down loader arms with system switched OFF. Rod side solenoid valve open. Check if solenoid operating, replace solenoid or selector valve as required. 2 Restricted loader arm suspension movement when switched ON. Rod side solenoid valve closed. Check if solenoid operating, replace solenoid or selector valve as required. 3 Springy loader arm lift with system switched OFF. Head side solenoid valve open. Check if solenoid operating, replace solenoid or selector valve as required.
4 No suspension, unable to power down when switched ON. Head side solenoid valve closed. Check if solenoid operating, replace solenoid or selector valve as required. 5 Accumulator gas pressure decrease. Leak across accumulator piston. Recharge, if frequent replace seals in accumulator. 6 Oil in gas side of accumulator. Leak across accumulator piston. Discharge, drain and recharge, if frequent replace seals in accumulator. 7 Increase in charge pressure. Oil to gas leak across accumulator Discharge, drain and recharge, if frequent piston. replace seals in accumulator. Note: It is normal for the loader arms to lift or lower slightly, when SRS is switched ON. Check fuse A1 replace as required.