JCB — Hydraulic Contamination

www.WorkshopManuals.co.uk Hydraulic Contamination Hydraulic Fluid Quality Contaminant Standards Construction machinery uses a large volume of fluid in the hydraulic system for power transmission, equipment lubrication, rust prevention and sealing. Dirt that damages your system is in many cases too small to be seen with the eye. The particle size is measured in microns. According to a survey conducted by a pump manufacturer, seventy per cent of the causes of problems in hydraulic equipment were attributable to inadequate maintenance of the quality of the hydraulic fluid.

1 micron= 0.001 mm (0.0000394 in) Listed below are a few typical comparisons:- Therefore, it is obvious that control of the quality of the hydraulic fluid helps prevent hydraulic equipment problems and greatly improves safety and reliability. Furthermore from an economic angle it extends the life of the hydraulic fluid if quality is maintained. Red Blood Cell = 8 microns (0.008 mm, 0.000315 in) Human Hair = 70 microns (0.07 mm, 0.00275 in) Grain of Salt = 100 microns (0.1 mm, 0.00394 in) Smallest particle visible to the naked eye is 40 microns (0.00157) approximately.

Effects of Contamination Standards will often be quoted to ISO (International Standards Organisation) for which literature can be obtained. Once inside the system, hydraulic circuit contaminants greatly effect the performance and life of hydraulic equipment. For example, contaminants in a hydraulic pump develop internal wear to cause internal leakage and hence lower discharges. Wear particles generated will circulate with the hydraulic fluid to cause further deterioration in the performance of this and other equipment. Filters The filter assembly fitted to all product ranges is designed to filter all the contamination that is generated through use to the required level of cleanliness.

The filter must be serviced to the requirements of the machine Service Schedules. Contaminants also enter principal sliding sections of the equipment causing temporary malfunction, scuffing, sticking and leakage and can lead to major problems. To ensure optimum performance and reliability it is important that the machines hydraulic system is serviced periodicaly in accordance with the manufacturers requirements. For service schedules refer to Section 3 Routine Maintenance . The main contaminants can be classified as follows:- 1 Solid Particles - sand, fibres, metallic particles, welding scale, sealing materials and wear particles etc.

2 Liquid - usually water and incompatible oils and greases. 3 Gases - Air, sulphur dioxide etc. which can create corrosive compounds if dissolved in the fluid. These contaminants can appear during manufacture, assembly and operation. Cleaning Operation The purpose of cleaning oil is to remove contaminants of all types and sludge by filtering hydraulic fluid through a cleaning unit, as illustrated or similar. General Bulletin 011 also refers. Procedure Connect the cleaning unit in place of the hydraulic filter and run the system for sufficient time to pump all the hydraulic fluid through the unit. Disconnect the cleaning unit and reconnect the filter.

Top up the system with clean hydraulic fluid as required. S168050 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 20 - 1 20 - 1 Service Procedures