www.WorkshopManuals.co.uk Variable Flow Pumps Flow and Pressure Testing Load Sensing Pressure Stand-by Pressure With no services operating, there should be no pressure in the load sense line, this is because hydraulic oil flows through the load sense circuit back to the hydraulic tank. If a shuttle valve is ‘stuck’, or a hose kinked, then a pressure could be induced in the load sense lines, this will have an effect on the hydraulic system. To check load sense pressure: With the engine switched off, the pump swashplate is spring loaded to the full flow position. On engine start up standby pressure moves the swash plate to minimum flow position (see descriptions). To check stand-by pressure:
1 Warm the hydraulic oil to working temperature, i.e. 50°C (122°F): 1 Warm the hydraulic oil to working temperature, i.e. 50°C (122°F): a Set the engine speed to 2200 rev/min. a Set the engine speed to 2200 rev/min. b Operate the loader shovel dump service to blow off the auxiliary relief valve. b Operate the loader shovel dump service to blow off the auxiliary relief valve. 2 Lower the backhoe bucket and loader shovel to rest on the ground; stop the engine; operate the control levers to vent residual hydraulic pressure. 2 Lower the backhoe bucket and loader shovel to rest on the ground; stop the engine; operate the control levers to vent residual hydraulic pressure.
3 Connect a 0 - 400 bar (0 - 6000 lbf/in 2 ) pressure gauge to pressure test connector B located on the pump pressure out line. 3 Connect a 0 - 400 bar (0 - 6000 lbf/in 2 ) pressure gauge to pressure test connector A located on the load sense line from the loader valve. 4 Start the engine and run at 2200 rev/min. 4 Start the engine and run at 2200 rev/min. 5 Do not move the steering wheel and make sure that all control levers remain in ‘neutral’ position. 5 Do not move the steering wheel and make sure that all control levers remain in ‘neutral’ position. 6 Check the pressure gauge reading, which should be as specified in Technical Data .
6 Check the pressure gauge reading, which should be as specified in Technical Data . 7 If the pressure is not as specified, do not make any adjustments at this stage. Complete the other checks detailed in this section. 7 If the pressure is higher than specified, first move the steering wheel and then any of the service levers. If this does not reduce the pressure, physically check the load sense lines for trapping or kinking. As a last resort, the service valves may have to be removed and checked for sticking shuttle valves. However, this should not be done until all other checks have been completed. 8 Refer to Regulator Valve Adjustment .
8 Machines with the load sense pressure relief valve adjust the load sense pressure relief valve E . Machines without a load sense pressure relief valve adjust the regulator valve. E S315770 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 22 - 2 22 - 2 Service Procedures