www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 22 - 6 22 - 6 Service Procedures Variable Flow Pumps Regulator Valve Adjustment (Cont’d) The load sense system is a dynamic type, which means a small flow (0.22 to 1.1 gall/1 to 5 litre per minute) is circulated through the load sense line. The flow is available due to a 0.02 in (0.6 mm) orifice in the flow regulator spool in the pump control housing. This orifice can be blocked or partially restricted which will give poor performance, slow operating speed and/or low maximum stall speed.
If completely blocked, margin pressure and stand-by pressure can be difficult to adjust and the loader services may operate intermittently even though the excavator operates correctly. If any of the above symptoms are experienced carry out the following: 1 Lower the backhoe bucket and loader shovel to rest on the ground. Stop the engine and remove the starter key. 2 Gain access to the regulator valve assembly. 3 Disconnect the load sense line at A. Attach a 0.25 inch (6.35 mm) hose to pump of suitable length to route to a measuring container. 4 Start the engine and measure the flow which should be at least 0.22 gall/1 litre per minute at 2200 RPM.
5 If the flow is below 0.22gall/1 litre per minute, remove spool B and clean/unblock orifice C as required. 6 Fit spool B and check the flow as described at step 3 and 4. 7 If the flow is within limits check the stand-by pressure. Refer to Flow and Pressure Testing. B B C A 347850 B B C A 347850