www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 22 - 7 22 - 7 Service Procedures Variable Flow Pumps Renewing Drive Shaft Seal Note: The following procedure describes renewal of the shaft seal. However this is not the normal sequence, the sealing ring would normally be assembled with the taper roller bearing from inside the pump to ensure a secure sealing condition. If the shaft seal is to be renewed in this manner, it is extremely important not to scratch or damage the shaft, otherwise leakage will occur.
1 Remove retaining ring 1 and use a special rounded tool such as a ground screwdriver to remove the drive shaft sealing ring 2. 2 Examine the seal running area (driveshaft and housing) for wear or damage. Damage in these areas will require the pump to be further dismantled. 3 Lubricate the new seal with JCB Special MPL Moly Grease. 4 Install the new seal, it is advisable to use a tube or similar located over the driveshaft to ensure the seal enters the housing evenly. DO NOT push the seal too far into the housing. If the shaft seal touches the bearing, the seal will be damaged. 5 Assemble the retaining ring 1. 2 S271880 1 2 S271880 1