JCB — Shuttle Valve Signal Network - Testing

www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 22 - 8 22 - 8 Service Procedures Variable Flow Pumps Shuttle Valve Signal Network - Testing The shuttle network can be easily checked. Start the engine and operate the hydraulic system until the oil is at working temperature. With the engine at 1500 revs/min operate each service in the following order: 1 Bucket 2 Dipper 3 Right Stabiliser 4 Left Stabiliser 5 Boom 6 Slew 7 Extradig 8 Lift 9 Shovel 10 Auxiliary 11 Steering Note: If your machine is not equipped with these valve sections, start with the furthest section from the pump and work back to the nearest section.

If one valve section function either fails to work or is slow to work in either one or both directions, the primary shuttle in that section may be at fault. If two or more valve sections next to each other fail to operate correctly, check the secondary shuttles. To check the secondary shuttle operate each service in sequence, the last correctly functioning service nearest the pump may have a secondary shuttle in that section at fault. When a shuttle is suspected of malfunctioning, do the following check: Stall any control valve that is near the pump than the suspected control valve. This should stall the entire system.

While at stall operate the malfunctioning valve section, if the section operates correctly the shuttle in question is at fault. If section still malfunctions the shuttle is NOT at fault. Shuttles may be removed, check the seals and the shuttle ball. Clean and refit or fit a new shuttle as required.