www.WorkshopManuals.co.uk 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 24 - 1 24 - 1 Service Procedures Ram Creep Tests - All Services If ram creep is suspected the following procedures must be carried out to define if the leakage is within tolerance. Ram creep can be caused by a number of reasons: Cylinder/Piston Leakage, Spool Leakage, ARV Leakage. The text and illustrations show a typical ram installation (in this instance the boom ram), the principle applies to all rams. Note: The procedures are not applicable for rams fitted with hose burst protection valves. ! WARNING Hydraulic fluid at system pressure can injure you.

Before disconnecting or connecting hydraulic hoses, stop the engine and operate the controls to release pressure trapped in the hoses. Make sure the engine cannot be started while the hoses are open. INT-3-1-11/1 ! WARNING Take care when disconnecting hydraulic hoses and fittings as the oil will be HOT. TRANS 1-2 A Test for Ram Creep 1 Operate the machine to bring the hydraulic oil to a normal working temperature of 50°C (122°F) which can be measured using a hydraulic oil temperature probe (service tool 892/00285). 2 Fit an appropriate pressure gauge A to a tee-piece in the service hose which is pressurised when the ram in question is supported (Fig 1).

3 Operate the rams to ensure they are full of hot oil. 4 Apply a load to the suspect ram for example the boom ram by raising the dipper to the horizontal as at B. 5 Measure the actual piston rod movement over 10 minutes. Measure the movement by checking the pivot pin to pivot pin dimensions as at C. Alternatively mark the rod with a felt tip pen 150mm (5.9 in) from the end cap and check the movement after 10 minutes, this is not possible on the majority of boom/extending dipper rams. 6 Using Table 1, check if the piston rod movement is within the recommended tolerance. If so, the ram creep is acceptable. Note: The table indicates the MAXIMUM permitted ram movement.

7 If the rate of movement is unacceptable, identify if the fault is as a result of cylinder/piston leakage or spool leakage at the control valve, see procedure B and C. 3 Operate the rams to ensure they are full of hot oil. 4 Apply a load to the suspect ram for example the boom ram by raising the dipper to the horizontal as at B. 5 Measure the actual piston rod movement over 10 minutes. Measure the movement by checking the pivot pin to pivot pin dimensions as at C. Alternatively mark the rod with a felt tip pen 150mm (5.9 in) from the end cap and check the movement after 10 minutes, this is not possible on the majority of boom/extending dipper rams.

6 Using Table 1, check if the piston rod movement is within the recommended tolerance. If so, the ram creep is acceptable. Note: The table indicates the MAXIMUM permitted ram movement. 7 If the rate of movement is unacceptable, identify if the fault is as a result of cylinder/piston leakage or spool leakage at the control valve, see procedure B and C. A C B C FIG 1 380190