www.WorkshopManuals.co.uk Fixed Flow Replacement Removal and Replacement Replacement is the reverse of the removal procedure. The following Procedure describes removal and replacement of a double section pump, follow the same procedure for single section pumps. 1 Clean off all traces of gasket compound from the pump and gearbox mounting faces. Apply a thin bead of JCB Multigasket to the gearbox mounting face. 2 Locate the splined shaft of the pump into the gearbox. Apply JCB Threadlocker and Sealer to bolts E and secure the pump flange to the gearbox mounting face. Removal ! WARNING Make the machine safe before getting beneath it.
Ensure that any fitments on the machine are secure; engage the parking brake, remove the starter key, disconnect the battery. 3 Reconnect the pump outlet hoses C and D to the elbow fittings. Note: All hydraulic adapters that are installed together with a bonded sealing washer must also have sealant JCB Threadseal applied to the threads of the adapter. INT-3-3-8 1 Remove the propshaft, refer to Section F Propshafts - Removal and Replacement . 4 Reconnect the pump inlet hose flange to the pump body with bolts B (4 off). 2 Drain the hydraulic fluid from the hydraulic tank. 3 Remove flange bolts B (4 off) and disconnect the pump inlet hose flange from the pump body.
Blank off all exposed connections to prevent ingress of dirt. 5 Fit the propshaft, refer to Section F Propshafts - Removal and Replacement . 6 Fill the system to the correct level with recommended hydraulic fluid, refer to Section 3 Fluids, Lubricants, Capacities and Specifications . 4 Disconnect the pump outlet hoses C and D from the elbow fittings. Blank off all exposed connections to prevent ingress of dirt. Note: Replace the suction strainer and return line filter after fitting a new or serviced pump. ! CAUTION The hydraulic pump is heavy. Do not attempt to remove the pump unless its weight is held by a sling. Make sure that the sling is attached to a suitable lifting appliance.
HYD 2-3 7 After fitting a new or serviced pump and before starting the engine screw the main relief valve out. Run the engine and check for leaks, also check the main relief valve (M.R.V.) operating pressure. Refer to Section E Service Procedures, Pressure Testing - MRV . 5 Secure the pump using a sling around the pump body, remove the pump mounting bolts E and carefully withdraw the pump clear of the gearbox. Torque Settings C Item Nm kgf m lbf ft B TBA E TBA D E B A396190 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 30 - 1 30 - 1 Main Pump