Hose Burst Protection Valves Pressure Testing - Loader Lift Ram (continued) Relief Valve Pressure Test If the hose burst protection valve has been stripped and cleaned, then pre-set the valve as detailed in step 1. The pressure test procedure is described in steps 2 to 6. 1 Pre-set the relief valve: a Remove cap B and its copper washer. Using an Allen key, turn the adjusting screw anti-clockwise to remove all tension. b Using your fingers, turn the adjusting screw clockwise until a soft force (resistance) is felt. c Using an Allen key, turn the adjusting screw a further 2 1 /4 turns to pre-set the relief valve. Refit the cap and washer. 2 Remove hose G from port C2.
Cap and plug the hose and valve port adapter (the valve port adapter MUST be plugged, otherwise the test procedure will not work). 3 Remove hose J from port V2. Plug the hose but DO NOT cap the valve port adapter. 4 Remove plug A and in its place fit a 0-400 bar (0-6000 lbf/in 2 ) pressure gauge connected to a hand pump. 5 Use the hand pump to increase the pressure. When the pressure reaches the setting of the relief valve, oil will escape from port V2, shown at K . Note the maximum gauge reading (the setting of the hose burst relief valve) which should be 250 bar (3625 lbf/in 2 ). 6 If necessary, adjust the pressure setting as follows: a Remove cap B and its copper washer.
b Using an Allen key, turn the adjusting screw clockwise to increase the pressure or anti- clockwise to decrease the pressure. For information; one full turn of the relief valve adjusting screw is equivalent to approximately 110 bar (1595 lbf/in 2 ). c Replace the cap and washer. d Repeat pressure test, adjust as necessary. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section E Hydraulics Section E 27 - 3 27 - 3 Service Procedures