www.WorkshopManuals.co.uk Removal and Replacement Manual Control ! WARNING Make the machine safe before working underneath it. Park the machine on level ground, lower the arms. Apply the parking brake, put the transmission in neutral and stop the engine. Chock both sides of all four wheels. 3 Disconnect all hydraulic hoses from the valve block and plug all orifices to prevent ingress of dirt. Label each hose before disconnecting, this will ensure correct position when refitting. * 4 Uncouple the dump solenoid electrical connector G . Uncouple the electric detent connector H (if fitted). Disconnect the battery, to prevent the engine being started while you are beneath the machine. GEN-1-2 !
DANGER * 5 Loosen and remove the three fixing nuts J . Remove the loader valve and spacing washers C . Hydraulic fluid at system pressure can injure you. Before disconnecting or connecting hydraulic hoses, stop the engine and operate the controls to release pressure trapped in the hoses. Make sure the engine cannot be started while the hoses are open. INT-3-1-11/1 Replacement Replacement is a reversal of the removal sequence. ! WARNING Fine jets of hydraulic fluid at high pressure can penetrate the skin. Do not use your fingers to check for hydraulic fluid leaks. Do not put your face close to suspected leaks.
Hold a piece of cardboard close to suspected leaks and then inspect the cardboard for signs of hydraulic fluid. If hydraulic fluid penetrates your skin, get medical help immediately. INT-3-1-10/1 Removal * Note: The illustration shows a valve fitted with a bolt on auxilary spool 1 . This item is only fitted to some machines, typically Precision Control machines with extending dipper. * 1 Operate the valve block levers back and forth to vent residual pressure. On Precision Control machines also operate the extending dipper foot pedal (if fitted). After replacement check the main relief valve (M.R.V.) and auxiliary relief valve (A.R.V.) pressure settings.
* 2 Remove clevis pins A and nuts B to disconnect the control levers from the valve block spools. Disconnect the control cable D (if fitted). Undo the lock nut E . Undo the housing fixing screws and slide it down the cable. Remove the pin F . Note: All hydraulic adapters that are installed together with a bonded sealing washer must also have JCB Threadseal applied to the threads of the adapter. 1 G B A F C J J H J E A402470 D 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 2* Section E Hydraulics Section E 50 - 1 50 - 1 50 - 1 Loader Valve - Fixed Flow 50 - 1