Air Conditioning System Operation (cont'd) System Control The refrigerant is drawn through the evaporator matrix E by the suction of the compressor. The temperature of refrigerant is now considerably below that of the air being drawn across the evaporator matrix by the blowers. Heat is transferred from the ambient and recirculated air to the refrigerant, causing the low pressure liquid to vaporise and become a low pressure gas. Moisture in the air condenses on the evaporator matrix and is drained away via condensate. Control of the system is achieved by the cyclic action of the compressor's electromagnetic clutch.
When current is fed to the field coil of the compressor's clutch, a magnetic field develops between the field coil and the armature which pulls the field coil, complete with clutch assembly, onto the compressor's rotor. Since the clutch assembly is turned constantly by the crankshaft pulley drive belt, the compressor armature turns, starting the refrigeration cycle. Current is fed to the field coil through three series switches whose contacts are controlled by the following: Cool de-humidified air is emitted through air vents into the cab. The low temperature, low pressure, high heat content refrigerant gas, is now drawn by suction back to the compressor, where the cycle is completed.
a The manual A/C ON/OFF switch F in the control console. b The freeze protection thermostat switch monitoring the evaporator temperature. Service connection points X and Y adjacent to the compressor are provided for connecting the pressure gauge manifold, when charging/testing the refrigerant. Connection X high pressure (red) and connection Y low pressure (blue). c The high and low level binary pressure switch. The ON/OFF switch F will start the refrigeration cycle provided that the ambient temperature in the cab is greater than 0°C and the refrigerant pressure remains within the specified limits. The thermostat has its sensor inserted in the evaporator matrix.
It controls the refrigeration cycle by switching the compressor clutch on and off to prevent freezing of the condensate on the evaporator matrix. The high and low level binary pressure switch assembly is located adjacent to the expansion valve on the HVAC unit. If the refrigerant pressure exceeds the upper pressure limit specified or falls below the lower limit, the contacts will open and the clutch will disengage, closing down the refrigeration cycle. Note: Switch settings are given in the technical data, refer to Technical Data - Air Conditioning (Option) . G H J F F A/C ON/OFF Switch G Turn to switch on the 3-speed heater fan. Turn further clockwise for faster speeds.
It functions only with the starter switch ON. H Temperature - Turn anti-clockwise to increase the heat. J Air Recirculation - Turn clockwise to recirculate air in the cab. Turn anti-clockwise for fresh air from outsde. The control can be adjusted to give a combination of recirculated air and fresh air. A401550 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 3 - 3 3 - 3 Basic Operation