JCB — Safety Procedures

Safety Procedures The air conditioning system includes a pressurised closed circuit containing a non-CFC, environmentally friendly refrigerant, Type R-134a. Any service procedure which breaks into the closed circuit and therefore requires discharging of the system, must only be carried out by service personnel with specialist knowledge of air conditioning systems. The following guidelines should be adhered to by all personnel servicing the air conditioning system. ! WARNING The air conditioning system is a closed loop system and contains pressurised refrigerant. No part of the system should be disconnected until the system has been discharged by a refrigeration engineer.

or a suitable trained person You can be severely frostbitten or injured by escaping refrigerant 4-3-4-1/2 ! CAUTION Do not operate the air conditioning system when there is no refrigerant in the system, otherwise the compressor will be damaged. 4-3-4-4 7 When checking the state of the refrigerant at the receiver drier sight glass, it is necessary to run the engine with the side panel removed and the bonnet raised. Extreme care must be taken to avoid moving engine parts such as fans, pulleys and belts. 8 Use caution when working near exposed evaporator fins. Painful cuts can be inflicted by the edges of the fins. Also, damage to the fins will reduce the efficiency of the system.

9 Make sure pressure cylinders are not over filled, particularly when recovering refrigerant. 10 Disconnect battery before doing any work. 1 It is critical that the correct refrigerant (R-134a) is used and that charging is done only by qualified personnel. It is illegal to discharge the refrigerant into the atmosphere but as a precaution in case of accidental leakage, discharging and charging of the vehicle refrigerant system must be conducted in a well ventilated area. 2 Containers of refrigerant should be stored in a cool environment away from direct sunlight. ! WARNING Do not carry out welding operations close to the air conditioning refrigerant circuit.

A poisonous gas is produced when refrigerant comes into contact with naked flames. Do not smoke or allow naked flames close to the refrigerant circuit. BF 1- 9 3 Do Not perform welding operations close to refrigerant hoses (maintain a distance of at least 0.5m from hoses). 4 Do Not steam clean refrigerant system components. 5 When charging or discharging the refrigerant system, no smoking or naked flames should be allowed in the immediate vicinity. The refrigerant does not give off a poisonous odour, however, when it comes into contact with a naked flame, a poisonous gas is produced. 6 When handling refrigerant, rubber gloves and goggles should be worn.

Operators should ensure no refrigerant comes into contact with the skin. Particular care should be taken when connecting or disconnecting charging hoses or pressure switches. When these components are connected to the system, a short release of refrigerant occurs. This results in a high velocity, very cold gas being emitted from the connection point. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 3 - 4 3 - 4 Basic Operation