Air Conditioning (cont’d) No Air Conditioning CHECK ACTION 1 Are the controls set correctly, i.e. air conditioning YES: Check 2 selected, thermostat switch set to coldest position NO: Reset controls and retest. and blower switched on? 2 Is the air conditioning (evaporator) blower working? YES: Check 3. NO: Check 4. 3 Is the compressor running (visual check of pulley/clutch)? YES: Check 9. NO: Check 5. 4 Is the air conditioning fuse(s) blown? YES: Renew fuse(s) and retest. NO: Check 8. 5 Is there a 12V supply to the pressure switch harness? YES: Check 6. Refer to Service Procedures - Pressure Switch Testing NO: Check 7. 6 Does the compressor clutch engage with YES:
Replace pressure switch assembly. pressure switch assembly bypassed? NO: Renew the compressor clutch and retest. Refer to Service Procedures - Pressure Switch Testing 7 Does the clutch engage with thermostat switch YES: Renew thermostat switch and retest. bypassed? NO: Check all electrical connections. 8 Are blower switch and wiring OK? YES: Renew blower unit complete. NO: Renew switch or wiring. 9 Is sight glass indication OK? YES: Check 10. NO: Charge check required by refrigeration engineer or suitably trained person. 10 Is condensor air flow blocked? YES: Clean condensor and radiator. NO: Check 11. 11 Is evaporator air flow blocked? YES: Clean filter and, if necessary the evaporator. NO:
Call in refrigeration engineer or suitably trained person. 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 10 - 2 10 - 2 Fault Finding