www.WorkshopManuals.co.uk Air Conditioning - System Diagnosis This section gives an overview of the following conditions: Note: Normal gauge readings will depend on system components and ambient conditions, make sure that the valves are closed and the readings are stable and that the system has a full charge. Normally Functioning A/C System Low R-134a Charge Poor Refrigerant Circulation No Refrigerant Circulation Insufficient Cooling of Condenser Air in System Expansion Valve Improperly Mounted Compressor Malfunction Moisture in the System The pressures on the manifold at 25 °C with the engine at 1500 RPM, the blower on maximum and the thermostat set to maximum, should be approximately:
Typically, the high pressure is 6 - 8 times the low pressure. Normally Functioning A/C System Gauge Readings: Low Side Gauge - Normal. High Side Gauge - Normal. 60 70 80 200 250 Other Indications: Sight Glass - Clear. Discharge Air - Cold. 40 50 90 100 100 150 300 30 20 350 120 110 50 400 350 10 0 30 0 500 450 B C A Component Key: A High Pressure/Temperature Gas. B Low Pressure/Temperature Gas. C High Pressure Liquid. A401380 9803/3280 Purchased from www.WorkshopManuals.co.uk Issue 1 Section B Body & Framework Section B 10 - 3 10 - 3 Fault Finding LOW SIDE (Blue) HIGH SIDE (Red) Normal Normal LOW SIDE - 2.0 bar (2.0 kgf/cm2)(29 lbf/in2) HIGH SIDE - 14.8 bar (15.1 kgf/cm2)(215 lbf/in2)